Sanyo CMH1822 Air Conditioner User Manual


 
4. COOLING CAPACITY
230V
CMH1822 / KMH0922 (×1)
5
WM700700
TC: Total Cooling Capacity (BTU/H)
SHC: Sensible Heat Capacity (BTU/H)
kW: Compressor Input (kW)
Remarks: Rating conditions (* mark) are: Outside ambient temperature 95°F DB
Indoor unit entering air temperature 80°F DB/67°F WB
Rating Capacity: 8,800 BTU/H Air Flow Rate: 220 CFM
Evaporator Condenser
Ent. Temp. °F/(°C) Ambient Temp. °F/(°C)
WB DB
75 85 95 105 115
(23.9) (29.4) (35.0) (40.6) (46.1)
TC 8,710 8,320 7,920 7,470 6,860
kW 0.62 0.67 0.73 0.79 0.87
59 72 (22.2) SHC 6,200 5,990 5,790 5,560 5,260
(15.0) 76 (24.4) SHC 6,940 6,740 6,530 6,300 6,000
80 (26.7) SHC 7,720 7,510 7,310 7,080 6,780
84 (28.9) SHC 8,460 8,250 7,920 7,470 6,860
88 (31.1) SHC 8,710 8,320 7,920 7,470 6,860
TC 9,010 8,730 8,390 7,930 7,300
kW 0.62 0.68 0.74 0.81 0.89
63 72 (22.2) SHC 5,260 5,120 4,960 4,740 4,460
(17.2) 76 (24.4) SHC 6,000 5,860 5,700 5,490 5,200
80 (26.7) SHC 6,780 6,640 6,480 6,260 5,970
84 (28.9) SHC 7,520 7,380 7,220 7,000 6,720
88 (31.1) SHC 8,260 8,120 7,960 7,740 7,300
TC 9,260 9,110 *8,800 8,320 7,740
kW 0.63 0.69 0.75 0.82 0.91
67 72 (22.2) SHC 4,280 4,220 4,080 3,870 3,630
(19.4) 76 (24.4) SHC 5,020 4,960 4,820 4,610 4,370
80 (26.7) SHC 5,800 5,730 5,600 5,390 5,150
84 (28.9) SHC 6,540 6,470 6,340 6,130 5,890
88 (31.1) SHC 7,280 7,220 7,080 6,870 6,630
TC 9,550 9,390 9,150 8,740 8,230
kW 0.63 0.69 0.76 0.84 0.93
71 72 (22.2) SHC 3,280 3,220 3,120 2,960 2,760
(21.7) 76 (24.4) SHC 4,020 3,960 3,860 3,700 3,510
80 (26.7) SHC 4,800 4,730 4,640 4,480 4,280
84 (28.9) SHC 5,540 5,470 5,380 5,220 5,020
88 (31.1) SHC 6,280 6,220 6,120 5,960 5,760
TC 9,730 9,630 9,420 9,080 8,710
kW 0.65 0.71 0.77 0.86 0.95
75 76 (24.4) SHC 3,020 2,980 2,910 2,790 2,660
(23.9) 80 (26.7) SHC 3,790 3,760 3,680 3,560 3,430
84 (28.9) SHC 4,540 4,500 4,420 4,300 4,180
88 (31.1) SHC 5,280 5,240 5,160 5,050 4,920