Sanyo CL4232 Air Conditioner User Manual


 
– 38 –
SM830078
9. ELECTRICAL DATA
Indoor Unit Outdoor Unit
Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz
Rating conditions
A 0.9 - 0.8 1.8 - 1.8 18.1 - 18.5 20.8 - 21.1
kW 0.2 - 0.16 0.36 - 0.34 3.67 - 3.62 4.23 - 4.12
Full load conditions
A 0.9 - 0.8 1.8 - 1.8 21.44 - 22.7 24.1 - 25.3
kW 0.2 - 0.16 0.36 - 0.34 4.49 - 4.48 5.05 - 4.98
Starting amperes A 1 - 1 2 - 2 131 - 131 134 - 134
Electrical characteristics
Indoor model: XS4232 / Outdoor model: C4232, CL4232
Indoor Unit Outdoor Unit
Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 - 208 V / 1 phase / 60 Hz 230 - 208 V / 1 phase / 60 Hz
Rating conditions
A 0.7 - 0.7 1.8 - 1.8 18.1 - 18.5 20.6 - 21.0
kW 0.16 - 0.14 0.36 - 0.34 3.67 - 3.62 4.19 - 4.10
Full load conditions
A 0.7 - 0.7 1.8 - 1.8 21.44 - 22.7 23.9 - 25.2
kW 0.16 - 0.16 0.36 - 0.34 4.49 - 4.48 5.01 - 4.96
Starting amperes A 1 - 1 2 - 2 131 - 131 134 - 134
Rating Conditions : Indoor Air Temperature 80 °F DB / 67 °F WB
Outdoor Air Temperature 95 °F DB
Full Load Conditions : Indoor Air Temperature 80 °F DB / 67 °F WB
Outdoor Air Temperature 115 °F DB
Indoor model: TS4232 / Outdoor model: C4232, CL4232