Sanyo C1251 Air Conditioner User Manual


 
38
Fig. 5b
7-1-2. Outdoor Unit
AVOID:
heat sources, exhaust fans, etc. (Fig. 4)
damp, humid or uneven locations.
DO:
choose a place as cool as possible.
choose a place that is well ventilated.
allow enough room around the unit for air intake/
exhaust and possible maintenance. (Fig. 5a)
Outdoor unit
Hot air
Heat source
Exhaust fan
NO
Fig. 4
Air intake Min. 6" (15 cm)
Air discharge
Min. 6"
(15 cm)
Min. 12"
(30 cm)
Valve side
Min. 10"
(25 cm)
Min.
7 ft.
(2 m)
Min.
7 ft.
(2 m)
Min. 6 in.
(15 cm)
Air intake
Ground
Obstacle
Obstacle above
Air discharge
Fig. 5a
CAUTION
Install the outdoor unit above snowfall line.
Do not place objects on or sit on the out-
door unit. Also, never block the air
intake/outlet or exhaust. Distortion of the
outdoor unit or incomplete combustion
may result.
Do not introduce foreign matter into the air
intake/outlet or exhaust. Do not poke them
with such objects as a stick.
provide a solid base (level concrete pad, concrete
block, 4 in. × 16 in. (10 × 40 cm) beams or equal), a
minimum of 4 in. (10 cm) above ground level to
reduce humidity and protect the unit against possible
water damage and decreased service life (Fig. 5b).
use lug bolts or equal to bolt down unit, reducing
vibration and noise.
7-1-3. Baffle Plate for the Outdoor Unit
(CL
×× models only)
It is recommended to use baffle plates for models
CL1251, CL1852 and CL0951. The baffle plates are not
normally required for the other models.
When the outdoor unit is installed in a position exposed
to strong wind (like seasonal winds with low air temper-
ature in winter), baffle plates must be installed on the
outdoor unit. (Fig. 5c)
This unit is designed so that the fan of the outdoor unit
runs at low speed when the air conditioner is operated
at low outdoor air temperatures. When the outdoor unit
is exposed to strong wind, the system pressure drops
because of the freeze protector.
NOTE
Air intake
Concrete
or equal
About 4" (10 cm)
Min. 4"
(10 cm)
Anchor bolts
(4 pcs)
About 16" (40 cm)
Air discharge
6" min
Air discharge
6" min
Baffle
plate
Baffle
plate
Fig. 5c
000-215 SM (1-56) 7/5/00 2:49 PM Page 38