Sanyo 18XS52 Air Conditioner User Manual


 
SUBMITTAL SHEET
SYSTEM
INDOOR/OUTDOOR
18XLS52 XS1852/CL1852
CEILING RECESSED (4-WAY) LOW AMBIENT AIR CONDITIONER
GENERAL DATA (AT 230V)
POWER V/PH/HZ 230/208/1/60
Circuit Ampacity, Min. (A) 15
Fuse size, Max (A) 20
COMPRESSOR Rotary-Hermetic
No. used 1
R.L. Amps - L.R. Amps (A) 7.8/8.4 - 43
Crankcase Heater 20W
OUTDOOR FAN TYPE Propeller
Dia. (in.) - No. used 16-17/32 - 1
Type Drive - No. speeds Direct - 1
No. Poles - RPM (High) 6 - 830
No. Motors - W 1 - 50
CFM (High) 1,390
F.L. Amps. (A) 0.5
OUTDOOR COIL - TYPE Aluminum Fin & Copper Pipe
Fin Type - Pipe Type Slit Plate - Inner Riffled
Rows - F.P.I. 2 - 24
Face Area (sq.ft.) 4.0
Tube Size (in.) 3/8
INDOOR FAN - TYPE Turbo
Dia. & Length (in.) - No. used 19-9/32 -1
No. speeds 3 & Auto
No. Poles -RPM (High) 6 - 451
No. Motors - W 1 - 40
CFM (HI/MED/LOW) 540/460/360
F.L. Amps (A) 0.6
INDOOR COIL - TYPE Aluminum Fin & Copper Pipe
Fin Type - Pipe type Corrugated Plate - Inner Riffled
Rows - F.P.I. 2 - 14.9
Face Area (sq. ft.) 3.2
Tube Size (in.) 3/8
Drain Connection Size (in.) 1-1/4
REFRIGERANT R22
Lbs. - R22 (O.D. Unit) 4.45
Control Capillary Tube
Connection Flare
Line Length, Max (ft.) 65
Lift difference, Max (ft.) 23
Line Size - in. O.D. Discharge 1/4
Line Size - in. O.D. Suction 5/8
DIMENSIONS (in.) H x W x D
Indoor Unit -Uncrated 12-29/32 x 33-27/32 x 33-27/32
-Crated 11-6/32 x 32-14/32 x 32-25/32 (Indoor unit)
4-3/32 x 38-2/32 x 39-11/32 (Indoor Grille)
Outdoor Unit -Uncrated21-19/32 x 34-21/32 x 13-5/32
-Crated 27-15/16 x 40-9/16 x 16-3/16
WEIGHT INDOOR OUTDOOR
Net (lbs.) 49.0/11.0(Grille) 104.0
Shipping (lbs.) 57.0/18.0(Grille) 112.0
Shipping Volume (cu.ft.) 6.9/ 3.5 (Grille) 10.6
SS18XLS52-2
PERFORMANCE DATA @ ARI STANDARD CONDITIONS (230/208V)
COOLING
Total Capacity (BTU/H) 18,000/17,500
Sensible Capacity (BTU/H) 12,000/11,000
Latent Capacity (BTU/H) 6,000/5,500
SEER 10.6/10.6
Dehumidification (Pints/H) 5.5/5.4
Amps (A) 8.2/8.77
Power Inputs (W) 1,780/1,740
Outdoor Sound Rating (bels) 7.8
FEATURE
Controls Microprocessor
Remote Controller LCD Wireless type
Temperature Control IC Thermostat
Timer ON/OFF, 24 hours
Night Setback Built-In
Air Louver (Horizontal) -
(Vertical) Automatic
Power Failure Automatic Restart Built-In
Self Diagnosis N/A
OPTION
Refrigerant Line Set AP2507BH (20 ft)
AP2510BH (30 ft)
AP2515BH (50 ft)
Low Ambient Control Built-in
Fresh Air Intake CMB-GSJ80T
Central Remote ON-OFF Control Available
Airduct Extension Available
Indoor Frame Extension N/A
Condensate Drain Pump Available
Non-Removable Remo-con Bracket RCS5PS4B
Wired Remote Controller RCS-102WD/RCS-302WD
OPERATING RANGE
Cooling Indoor Air Outdoor Air
Intake Temp. Intake Temp.
Maximum 95 F B/71 F WB 115 F DB
Minimum 67 F B/57 F WB 0 F DB
CERTIFICATION
18XLS52
AIRCONDITIONING PRODUCTS