Dimensions
Heating
Amps
Max. Amps
Power Inputs
Back-up Strip Heater
Outdoor Sounds Rating
Features
Controls
Remote Controller
Temperature Control
Timer
Night Setback
Air Louver
Power Failure Automatic Restart
Self-Diagnosis
Air Filter
Air Clean Apatite Filter
Quiet Operation
Ion Generator
Options
Refrigerant Line Set
Fresh Air Intake
Airduct Extension
Condensate Drain Pump
Hard Wired Remote Controller
Non-Removeable Locking Remo-con Bracket
Operating Range
Indoor Air Intake Temp. Outdoor Air Intake Temp.
Cooling
Indoor Air Intake Temp. Outdoor Air Intake Temp.
Heating
Maximum 95F DB/71F WB 115F DB
Minimum 67F DB/57F WB 0F DB
Built-In
Washable, Anti-Mold
Built-In
Available
Knock-out
N/A
Standard
Available
Microprocessor
LCD Wireless Type, Temp. Sensor Built In
(Horizontal) Manual
24 Hr Program; 1HR ON/OFF
IC Thermostat
Built-In
(Vertical) Automatic
Sanyo Commercial Solutions
A Division of SANYO North America
1300 Michael Drive
Wood Dale, IL 60191 USA
www.sanyohvac.com
Available
Standard
Built-In
Built-In
3. DIMENSIONAL DATA
Indoor Unit XHS1271 & PNR-XS1872
XHS1872 & PNR-XS1872
6-5/16 6-11/16
1-3/16 (30)
4-19/32
1-25/32
1-25/32
2-3/32
8-15/32
22-5/8 (575)
11-5/32 (283)
3
6
5
Less than 31/32 Less than 31/32
3-5/8
22-5/8 (575)
12-7/8
Suspension bolt pitch
Suspension bolt pitch
21-1/32 (534)
21-1/32
(534)
12-7/16
23-5/8 (600)
Ceiling opening dimensions
23-5/8 (600)
Ceiling opening dimensions
7
Center of
panel
24-19/32 (625)
24-19/32 (625)
13-5/32 (334)
14-3/32 (358)
1
2
2
2
2
7-11/16
4-29/32
A View
8
1-3/16
21/32
3-1/8
The length of the suspension
bolts should be selected so that
there is a gap of 1-3/16" or
the ceiling (21/32" or more
below the lower surface of the
main unit), as shown in the
figure at right. If the suspension
bolts is too long, it will contact
the ceiling panel and the unit
cannot be installed.
AA
Air intake
Discharge outlet
Refrigerant tubing
(liquid tube)
dia.
1/4" (flared)
Refrigerant tubing
(gas tube)
dia. 1/2"
(flared)
Drain tube connection port VP20 (outer dia. 1")
Power supply port
Suspension bolt hole (4 - 1/2" x 1-1/8" hole)
Fresh air intake duct connection port (dia. 3-7/8")
1
2
3
4
5
6
7
8
7-23/32
1-27/32 1-3/32
2-3/32
2-3/4 1-9/32
5-9/16
25/32
Unit : inch (mm)
17
10-13/16
3-19/32
ID:23/32
4-ID:15/16
21-3/16
6-3/32
4-9/32 2-5/32
Narrow tube service valve
dia.1/4" (6.35)
Wide tube service valve
dia.3/8" (9.52)
3-19/32
15/32
10-7/16 (265)
11-13/32
12-7/16
Outdoor Unit CH1271
Unit : inch (mm)
(852-0-0010-12700-0)
28-11/32 (720) 2-1/8
21-9/16 (548)
5/8
18
(dB-A) 51
(W) 2340/2340(270-2340)
0.00/0.00
(A) 10.5(1.3/10.5)
-
Maximum 80F DB/67F WB 75F DB/65FWB
Minimum -DB/-WB 0F DB