Sanyo 09KS51 Air Conditioner User Manual


 
SUBMITTAL SHEET
SYSTEM
INDOOR/OUTDOOR
09KLS51
KS0951/CL0951
WALL MOUNT LOW AMBIENT AIR CONDITIONER
GENERAL DATA (AT 115V)
POWER
V/PH/HZ 115/1/60
Circuit Ampacity, Min. (A) 15
Fuse size, Max. (A) 15
COMPRESSOR Rotary-Hermetic
No. used 1
R.L. Amps - L.R. Amps (A) 7.7-49
Crankcase Heater 20W
OUTDOOR FAN - TYPE Propeller
Dia. (in.) - No. used 16-17/32 - 1
Type Drive - No. speeds Direct - 1
No. Poles - RPM (High) 6 - 600
No. Motors - W 1 - 21.6
CFM (High) 1020
F.L. Amps. (A) 0.7
OUTDOOR COIL - TYPE Aluminum Fin & Copper Pipe
Fin Type - Pipe Type Slit Plate - Inner Flat
Rows - F.P.I. 1 - 18
Face Area (sq.ft.) 4.2
Tube Size (in.) 3/8
INDOOR FAN - TYPE Cross-flow
Dia. & Length (in.) - No. used 3-3/4 & 24-9/32-1
No. speeds 3 & Auto
No. Poles -RPM (High) 4-1,200
No. Motors - W 1 - 18.2
CFM (HI/MED/LOW) 270/240/220
F.L. Amps (A) 0.4
INDOOR COIL - TYPE Alminum Fin & Copper Pipe
Fin Type - Pipe type Slit Plate - Inner Flat
Rows - F.P.I. 2 - 18
Face Area (sq. ft.) 1.4
Tube Size (mm) 7
Drain Connection Size (in.) 23/32
REFRIGERANT R22
Lbs. - R22 (O.D. Unit) 1.28
Control Capillary Tube
Connection Flare
Line Length, Max (ft.) 50
Lift difference, Max (ft.) 23
Line Size - in. O.D. Discharge 1/4
Line Size - in. O.D. Suction 3/8
DIMENSIONS (in.) H x W x D
Indoor Unit -Uncrated 10-5/8 x 31-11/16 x 6-31/32
-Crated 9-13/16 x 33-21/32 x 13-5/16
Outdoor Unit -Uncrated 21-1/4 x 31-1/2 x 11-13/32
-Crated 23-31/32 x 38-5/8 x 16-3/16
WEIGHT INDOOR OUTDOOR
Net (lbs.) 17.6 66.1
Shipping (lbs.) 22.0 75.0
Shipping Volume(cu.ft.) 2.51 8.67
SS09KLS51-2
PERFORMANCE DATA @ ARI STANDARD CONDITIONS (115V)
COOLING
Total Capacity (BTU/H) 9,000
Sensible Capacity (BTU/H) 6,420
Latent Capacity (BTU/H) 2,580
SEER 10.0
Dehumidification (Pints/H) 2.0
Amps (A) 8.8
Power Inputs (W) 900
Outdoor Sound Rating (bels) 7.0
FEATURE
Controls Microprocessor
Remote Controller LCD Wireless type
Temperature Control IC Thermostat
Timer ON/OFF, ProgramTimer
Night Setback Built-In
Air Louver (Horizontal) Manual
(Vertical) Auto
Power Failure Automatic Restart Built-In
Self Diagnosis N/A
OPTION
Refrigerant Line Set AP0905BH (15 ft)
AP0907BH (20 ft)
AP0910BH (30 ft)
Air Clean-Filter STK-ARF4B
Fresh Air Intake N/A
Central Remote ON-OFF Control Available
Airduct Extension N/A
Indoor Frame Extension N/A
Condensate Drain Pump Optional
Non-Removable Remo-con Bracket Optional
OPERATING RANGE
Cooling
Indoor Air Outdoor Air
Intake Temp. Intake Temp.
Maximum 95 F DB/71 F WB 115 F DB
Minimum 67 F DB/57 F WB 0 F DB
CERTIFICATION
09KLS51
AIRCONDITIONING PRODUCTS