TROUBLESHOOTING
SYMPTOM: Unit will not turn on.
Problem: Not plugged in.
Solution: Plug machine in proper outlet.
Problem: Circuit breaker has popped.
Solution: Reset circuit breaker. Make sure no other items are running on the
same circuit as machine. Outlet must be a 20-amp circuit.
Problem: Power cord has become disconnected from extension cord.
Solution: Reattach power cord to extension cord.
SYMPTOM: Pump is not running properly.
Problem: Power cord and extension cord are not completely locked together.
Solution: Snap rmly together.
Problem: Jets on wand are clogged.
Solution: Clean jet with soft wire brush or remove jet and ush clean.
Problem: The solution tank is empty.
Solution: Fill the solution tank up with a pre-mixed detergent.
Problem: Pump is pulsating.
Solution: Tighten all hoses. Check for leaks.
SYMPTOM: Vacuum motor not working properly.
Problem: Hose not connected tightly to wand or machine.
Solution: Connect hose tightly.
Problem: Hose is clogged with hair, carpet bers and/or debris.
Solution: Clean hose.
Problem: Drain plug is not shut completely.
Solution: Close drain plug completely.
Problem: Vacuum tank lid is not on tightly.
Solution: Secure the vacuum tank lid on tightly.
Problem: Vacuum tank lid is cracked.
Solution: Replace the vacuum tank lid.
Problem: Vacuum hose is cracked or split.
Solution: Replace vacuum hose.
Problem: Water is coming out of the vacuum motor.
Solution: Use a low foaming detergent.
10