Sanitaire SC5800 Series Vacuum Cleaner User Manual


 
ROUTINE MAINTENANCE (continued)
Pre-Motor
Filter
Pre-Motor Filter
Check the pre-motor filter each time the dust cup is emptied.
Clean or replace as needed.
To Clean Pre-Motor Filter
1. Remove filter centered in the bottom of the dust cup
compartment.
2. Shake filter to remove excess dust. If necessary, the filter
can be cleaned by vacuuming with another cleaner or
washing with mild detergent.
3. Reinstall filter after completely dry.
Use GENUINE EUREKA replacement pre-motor filter,
Part No. 71480.
Filter Door Latch
True HEPA Cartridge
Latch
Models equipped with Cartridge Filter (Only
cartridge style filters can be used with these models.)
Check the True HEPA filter each time dust cup is emptied.
Replace twice a year or as needed.
To remove True HEPA
cartridge
filter
1. Push down on filter door latch and pull door away from
cleaner.
2. Push down on HEPA cartridge latch and remove filter.
To replace True HEPA
cartridge
filter
1. Place bottom tabs of filter cartridge into slots. Rotate
filter toward cleaner, press firmly against cleaner to latch.
Make sure True HEPA cartridge latch is secured on
both sides.
2. Replace filter door by placing tabs of door into slots on
cleaner. Rotate door up and against cleaner until it locks
into place.
NOTE: To have the benefit of a sealed True HEPA
system, you must use one of the True HEPA
cartridge
filter systems.
Use GENUINE EUREKA replacement True HEPA filter,
HF5.
PERIODIC MAINTENANCE
How To Change Light Bulb (Only for models with a
headlight)
NOTE: Turn off the power switch and disconnect the
electrical cord before changing light bulb.
1. Lower handle. Remove the screw from lens cover.
2. Pull lens cover from cleaner.
3. Pull old light bulb out of socket.
4. Push new light bulb into socket.
5. Replace lens cover.
6. Secure with screw.
Use GENUINE EUREKA replacement light bulb,
Part No. 57940-2.
9
How To Clean Filters
1. Remove from cleaner.
2. To remove debris, tap filter against waste container or brush
off. You may also vacuum the filter using a different cleaner.
If filter needs further cleaning, wash in warm water using a
mild detergent. To clean between filter pleats, fan open
under running water.
3. When all parts are completely dry, follow the above
steps in reverse to reassemble.
NOTE: Do not put any parts in a dishwasher.
NOTE: Your washable filter may need to be replaced if
cleaning it does not restore cleaning performance.
Be sure to use GENUINE EUREKA replacement filter.