Samsung UD26B1C2 Air Conditioner User Manual


 
20
3-4 Set up the Model option
• It is necessary to set up option code after replacing the main-PCB as a service parts.
Make sure that you can set up the option of code the remote controller after you replace the main
PBA otherwise, the unit won’t be working properly and all LED lamps on display will be flickering.
Step 1 : Preparing the remocon to main PCB option set
1
st
Remove the battery from the remocon.
2
nd
Press the temperature raise/down button simultaneously
and insert the battery again.
3
rd
Make sure the remocon display shown as .
Step 2 : Second stage preparation of the remocon option set.
The Method for Setting up the model option with remocon
Note ; In case the wrong letter has been selected, continue to press the button until the correct letter appears.
1
st
If the first stage number “ ” appears on the display, proceed to the second stage.
2
nd
Every time the ! and & button, “ ” and “ ” each continue to appear.
3
rd
Whenever pressing the @, #, $, %, ^, *, (, ), 1, 2 button, the number increase from
0~9(0123456789) and A, b, C, d, E, F each time.
! If the first number is , it is correct otherwise press until
appear.
@ When pressing the button ~ appear on the display,
select one of them.
# When pressing the button ~ appear on the display,
select one of them.
$ When pressing the button ~ appear on the display,
select one of them.
% When pressing the button ~ appear on the display,
select one of them.
^ When pressing the button ~ appear on the display,
select one of them.
DB98_05645A(1)_1 5/30/02 7:05 PM Page 20