Samsung SSA-P401T Home Security System User Manual


 
6_ product introduction
product introduction
Input Port Format Setup
15 input ports are provided by default. For these ports, you can specify if the format of the incoming signal is
blocked (NO) or connected (NC) in normal operation. This setting will make all ports operate same regardless of the
output status of the input device.
Time Scheduling
You can specify a time range during which a specifi c operation is performed. You can specify a specifi c time range
for a schedule code, which will be transferred to the applicable device. You can specify up to 5 different time
intervals for a day, ranging from Monday to Sunday including holidays. Each time schedule code can produce a
single different (or same) holiday code.
Door Open Alarm and Forced Door Open Alarm
The Door Open Alarm function notifi es the administrator that the door is still open if a door stays open after the
normal door open time and the standby time. (The output signal can be transferred via the output port, data on any
abnormal state will be stored in memory, which will be transferred upon request from the PC software. The Forced
Door Open Alarm function produces an alert when the door is forced to open and makes an alert again if the door
is still open after the timeout.
I/O Settings
This product is equipped with 15 input ports, 12 relay output ports, and 3 TTL output ports. You can use the
input ports to receive signals from the Exit button and the fi re sensor, and utilize this product to meet various
situations such as attaching the door lock to any of the 12 relays. You can also set the output time for these
output ports.
Holiday Setup
You can specify a holiday (legal holiday or bi-weekly holiday) excluding Sunday. You can specify up to 100 holidays
for a single holiday code. (Access can be permitted only for an allowable time range according to your time
schedule setting) A holiday code can be assigned to the time schedule code.
ARM/DISARM
In the condition where the ARM/DISARM code is specifi ed, if you enter the ARM/DISARM code and present the
card of the administrator (with master permissions) to the reader, the device triggers the alarm mode where you
can control the output signal in sync with the security system. In this mode, all connected readers will not take the
card input any further.
Duress Mode
This is used in a situation where you should open the door inevitably by a robber insisting to do so. Open the door
by entering the two-digit duress alarm password and pressing the
button before presenting the registered card
(or recognizing the card number), in the meantime this forcibly duress situation will be notifi ed to the PC application.
Two Men Operation Mode
This will allow access by visitors only under the control of the visitor guide.
Access will be permitted only if two cards are presented within a specifi ed time (10 seconds).
Dual Door Time Control
This allows you to specify two different settings for the entrance door control time according to the passers-by.
However, this can not be enabled with the ARM/DISARM function at the same time.
Data Maintenance
In the event of power failure, the controller retains all card information and the access/alert history (event data) until
it is damaged on the memory.
You can use the application program (SAMS Basic) to confi gure all theses settings to your preference.