Samsung NS035NHXEA Air Conditioner User Manual


 
E-24
Temperature and Humidity Ranges
Operating Recommendations
Here are a few recommendations that you should follow when using your air conditioner.
Topic Recommendation
Heating performances The heat pump function of the air conditioner absorbs heat from outside air and brings it
indoors. As the temperature of the outside air drops, the heating performance of air
conditioner will decrease. If you find that the room is not warm enough, using an additional
heating appliance is recommended.
Warm air circulation The air conditioner circulates warm air to heat your room. It will take some time to warm the
air in your room entirely after the air conditioner turns on. Therefore, turn the air conditioner on
in advance.
Frost When outside temperature is low but humidity is high,
frost may form on the outdoor unit at HEAT mode.
If this happens:
The heating operation stops.

The defrost mode will be triggered automatically for about 10 minutes.

The steam produced on the outdoor unit in the defrost mode is safe.
No intervention is required ; after about ten minutes,the air conditioner operates again normally.
High indoor and
outdoor temperatures
If both indoor and outdoor temperatures are high and the air conditioner is running at HEAT
mode, the outdoor unit’s fan and compressor may stop at times. This is normal;simply wait until
the air conditioner switches on again.
Power failure If a power failure occurs while the air conditioner is operating, the unit will be switched off.
When the power returns, the air conditioner starts up again automatically.
Protection mechanism When the air conditioner is started immediately after being plugged in or stopped, the normal
operation starts up after 3 minutes for the reason of protection.
Cooling operation The indoor unit may not get the selected fan speed such as Medium and Low under cooling
operation at very low outdoor temperatures for the protection of the indoor unit from ice
or frost.
During Low fan speed operation, cooling performance will be reduced. If the room does not be
cooled down when using Low fan speed operation, please adjust the indoor unit’s fan speed.
The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to
the table for efficient use
.
MODE OPERATING CONDITIONS IF OUT OF CONDITIONS
COOL
Indoor temp: 18°C~32°C
- A safety device will stop continuously the
system functioning;
- Condensation may occur on the indoor unit
with risk to have either water blow off or drops
on the floor;
Indoor humidity: below 80%
Outdoor temp: -10°C~43°C(UH026/35EAV)
Outdoor temp: -15°C~43°C(UH052/70EAV)
HEAT
Indoor temp: below 27°C
- A safety device will stop continuously the
system functioning;
Outdoor temp: -15°C~24°C(UH026/35EAV)
Outdoor temp:
-20°C~24°C(UH052/70EAV)
DEHUMIDIFYING
Indoor temp: 18°C~32°C
- A safety device will stop continuously the
system functioning;
- Condensation may occur on the indoor unit
with risk to have either water blow off or drops
on the floor;
Indoor humidity: below 80%
Outdoor temp: -10°C~43°C(UH026/35EAV)
Outdoor temp: -15°C~43°C(UH052/70EAV)
POWER SUPPLY
Single phase rated voltage
minimum and maximum limit
220V-240V~,50Hz
198V min.-264V max.
Any damage occurs out of condition specified cannot be covered by product warranty.
If the system works continuosly outside of conditions, its performace and reliability will be compromised.