Samsung AQ24A1(2)RCD Air Conditioner User Manual


 
Technical Specifications
Standard rating conditions Cooling
Indoor
DB
80
26.7
°F
°C
WB
67
19.4
DB
95
35.0
WB
75
23.9
Outdoor
Heating
Indoor
DB
70
21.1
°F
°C
WB
60
15.6
DB
47
8.3
WB
43
6.1
Outdoor
E-26
MODEL
INDOOR UNIT
OUTDOOR UNIT
Performance
Ratings
Capacity Cooling
Capacity Heating
HSPF
SEER
Moisture Removal
Air FLOW(Cooling, HIGH)
Air FLOW(Heating, HIGH)
Sound Rating-Outdoor
Btu/h
Btu/h
Pts/h
CFM
CFM
dB
Electrical
Data
Power source
Min.Ampacity
Cooling Watts
Heating Watts
A
W
W
Refrigeration
Lines
Connections
Liquid Line O. D.
Suction Line O.D.
Factory Pre-charge
Max. Line length
Max. Height Difference
inch(mm)
inch(mm)
ft(m)
ft(m)
ft(m)
Dimensions
& Weight
W X H X D
Net Weight
inch(mm)
Ibs(kg)
W X H X D
Net Weight
inch(mm)
Ibs(kg)
AQ09A5(6)MAF
9000
9500
7.0
10.0
3
230
247
51
115V~, 60Hz
8.1
950
870
Flare
(6.35)
(9.52)
23(7.0)
AQ09A5(6)MAF
(660 x 497 x 235)
UQ09A5(6)MAF
21.2(9.6)
26
60.7(27)
19
1
2
xx
9
1
4
(7.5)
( 24
3
4
(15.0)
( 49
1
4
(790 x 245 x 165)
( 31
1
8
)
9
1
2
xx
6
1
2
1
4
3
8
AQ12AA(B)MCF
11500
12500
6.8
10.0
4
261
286
55
5.4
(7.5)
( 24
3
4
(15.0)
( 49
1
4
23(7.0)
208-230V~, 60Hz
1230
1300
Flare
AQ12AA(B)MCF
UQ12AA(B)MCF
21.2(9.6)
(790 x 245 x 165)
( 31
1
8
)
9
1
2
xx
6
1
2
73.2(33)
(740 x 530 x 230)
29
20
3
4
xx
9
(6.35)
1
4
(12.70)
1
2