Robertshaw Deluxe Programmable Thermostat Thermostat User Manual


 
Menu Driven Display
1 Heat / 1 Cool
Terminal Designations
Specifications
Electrical rating: 24 Volt AC (18-30 VAC)
1 amp maximum load per terminal (relay outputs)
3 amp total maximum load (all terminals combined)
Temperature control range: 45˚- 90˚F (7˚- 32˚C)
Accuracy: +/-1.0˚F (+/-0.5˚C)
Power Source: 24 VAC
Auto Changeover deadband: Selectable 2˚ to 8˚F
Temporary temperature override: 3 hour maximum or next setpoint
Remote sensor capable: 1 indoor and 1 outdoor sensor
System configurations: Single-stage gas, oil or electric
heating/cooling systems and single stage heat pump
Terminations: R, W1, Y1, B, O, G, C, IS, OS, H
Other Single Stage
Heat / Cool Thermostats
9200: Mercury-Free Deluxe Mechanical
9600: Programmable, 5-2 Day
9610: Programmable, 7 Day
9700i: Deluxe Programmable, 7 Day
9801i: Humidification, 7 Day
9901i: Commercial, 7 Day
Shipping Information
Indiv. Ctn. Dim.: 6.625" x 4.25" x 1.625"
Master Ctn. Qty.: 6
Master Ctn. Dim.: 9.25" x 5.625" x 7.5"
Master Ctn. Cu. Ft.: .23
Master Ctn. Wt.: 3.5 lbs.
Max. Pallet Qty.: 1260
Max. Pallet Wt.: 785 lbs.
Optional Sensors:
REMOTE INDOOR
REMOTE OUTDOOR
Distributed by:
Dehumidity
Relay
D
PC8900
P374-1100, THERMIDISTAT
1F97-391
THE ROBERTSHAW
REPLACES:
98
5
1
White-Rodgers*
®
9020
i
902
5
i
Item 9020i and 9025i Remote Sensors
Indiv. Ctn. Dim.: 2.625" x 1.5625" x 4.4375"
Master Ctn. Qty.: 6
Master Ctn. Dim.: 5.625" x 5.125" x 5.125"
Master Ctn. Cu. Ft.: .09
Master Ctn. Wt.: .78 lbs.
Feature Comparison
EG
ELECTRIC
O
OILGAS
H
HEAT PUMP
DELUXE
PROGRAMMABLE
THERMOSTAT
98
5
1
Controls Americas
515 South Promenade Avenue
Corona California 92879-1736 USA
Telephone +1 800 951 5526 Facsimile +1 630 260 7299
iccacustomerservice@invensys.com
Technical Service Telephone +1 800 445 8299
Technical Service Facsimile +1 630 260 7243
technicalservice@invensys.com
www.icca.invensys.com
©2005 Invensys Controls Americas 9/05 - #150-1808B
Robertshaw Honeywell, Inc. Carrier Corp.
9851i PC8900 THERMIDISTAT
Manual Override X X X
EEPROM X X X
Compressor Short Cycle Protection X X X
7 Day Programming X X X
Resume X X X
Auto Changeover X X X
Line Powered X X X
Programmable Fan X X X
O & B Terminals X X Partial
˚F and ˚C X X X
Status Indicators X X X
Adjustable Differential X X X
Gas/Electric X X X
Energy Efficient Recovery X X
Manual Humidity Control X X X
Automatic Humidity Control
based on Outdoor Temperature
XX X
Dehumidity Control X X X
Pre-Set Program X X X
Independent Humidity & Dehumidity Control X
4 Hour Reserve X X X
Events / day 2, 4 4 4
Hidden Service Level X X X
Remote Outdoor Sensor X X X
Security Key Pad X X X
Vacation Setting X X X
Air Filter Monitor X X X
12 or 24 Hour X X
Condensation Control X X
Remote Indoor Sensor X X
Large Display X X
Back Lighting X X
Service Interval Reminders X
5/2 Day Programming X
Adjustable Residual Cooling X
1/2 Degree Resolution X
Menu Driven (Ease of Programming) X
24 Hr. Programming X
All marks shown are the property of their respective owners.