Roberts Gorden UHA[X][S] 125 Gas Heater User Manual


 
SECTION 15: SPECIFICATIONS
49
SECTION 15: SPECIFICATIONS
15.1 Dimension Data
MODEL
UHA[X][S]
30
UHA[X][S]
45
UHA[X][S]
60
UHA[X][S]
75
UHA[X][S]
100
UHA[X][S]
125
'A' Height
in
(cm)
12
(30.48)
12
(30.48)
17.75
(45.09)
17.75
(45.09)
23
(58.42)
23
(58.42)
'C' Center of Flue [Top
Option]
in
(cm)
5.2
(13.21)
5.2
(13.21)
5.2
(13.21)
5.2
(13.21)
6.9
(17.53)
6.9
(17.53)
'D' Center of Flue
in
(cm)
2.5
(6.35)
2.5
(6.35)
2.5
(6.35)
2.5
(6.35)
2.5
(6.35)
2.5
(6.35)
Recommended Mounting
H ei ght to H ea ter Ba se
ft
(m)
10
(3.05)
10
(3.05)
12
(3.66)
12
(3.66)
20
(6.10)
20
(6.10)
20.25"
(51 cm)
25.5"
(65 cm)
1. 8"
(5 cm)
16.63"
(42 cm)
28.5"
(72 cm)
3 .3"
(8 cm)
REAR VIEW
TOP VIEW
Gas Supply
Flue
Air
Intake
(UHA[X]S
only)
D
SIDE VIEW
C
Air Intake
(UHA[X]S only; Optional Position)
Flue
(Optional Position)
4 x 3/8" Captive Nuts Provided
17.63"
(45 cm)
18.25"
(46 cm)
Electrical
Supply
Thermostat
Connection
A
6"
(15 cm)
1.5" (4 cm)
6.75"
(17 cm)
6"
(15 cm)
6"
(15 cm)
6.75"
(17 cm)