Roberts Gorden CRV-B-6 Gas Heater User Manual


 
SECTION 17: GENERAL SPECIFICATIONS
59
General Specifications for pumps are as follows:
* For starter, see National Electric Code (NEC) requirement for motors 1 hp or higher.
Air Supply Blower Specifications
Capacity 240 CFM @ 0.75 in wc
Power (W) 167
Phase 1
Hertz (Hz) 60
Voltage (V) 120
Full Load Amp (Amps) 1.5
R.P.M. 3000
Motor Enclosure OPEN FC
Inlet/Outlet (In.) 5/5
Weight (lbs.) 10
C
B
G
A
E
D
F
dia.
Pump Specifications
Model EP-100 EP-201 EP-203 EP-301 EP-303
Horsepower (Hp) 1/3 3/4 3/4 2* 2*
Phase (Ø) 11313
Hertz (Hz) 60 60 60 60 60
Voltage (V) 115/230 115/230 208-230/460 208-230 208-230/460
Full Load Amp (Amps) 4.8/2.4 6.6/3.3 2.4-2.2/1.1 12.8-11.5 5.5-5.2/2.6
R.P.M. 3450 3450 3500 3450 3450
Motor Frame 56 56 56 90 90
Motor Enclosure TENV TENV TEFC TEFC TEFC
Noise Level @ 5' (DBA) - 70 70 - -
Inlet/Outlet (In.) 4/4 4/4 4/4 6/6 6/6
Weight (lbs.) 62 112 112 170 170
Pump Dimensional Data (in.)
Model A B C D E F G
EP-100 17 14.5 21 3.75 10 4 4
EP-201/203 17.75 17 20.25 3.25 10 4.5 4.5
EP-301/303 25.6 24.8 22.7 4.8 15.2 6 6