Rinnai R75LSI (VA2528FFUD) Water Heater User Manual


 
3.6 (91)
14 (355.6)
9.6 (244.5)
22.9 (582)
25.5 (648.2)
4.3 (110)
1.1 (27)
3.5 (89)
3.9 (99
)
2.8 (70)
R75LSi (VA2528FFUD)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
Water Temperature Control
Controller
Controller Cable
Safety Devices
Clearances from Combustibles
(suitable for closet, attic, and
crawl space installations)
Clearances from Non-combustibles
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.)
NOx
Warranty
Simulation feed forward and feedback
MC-91-1US (part of the front panel)
Deluxe controller: MC-100V-1US (optional)
Bathroom controller: BC-100V-1US (optional)
Wireless controller: MC-502RC-1US-MS (optional)
MCC-91-1US (for commercial applications)
Non-polarized two-core cable, minimum 22 AWG
Flame failure - Flame Rod
Boiling protection
Combustion fan rpm check
Over current - glass fuse (3 amp)
Top of heater - 6 inches
Front of heater - 6 inches
Sides of heater - 2 inches
Top of heater - 2 inches
Front of heater - 6 inches
Sides of heater - 1/2 inch
Natural Gas: min 5” W.C. max 10.5” W.C.
Propane Gas: min 8” W.C. max 13.5” W.C.
Natural Gas: high fire 2.7” W.C. low fire 0.52” W.C.
Propane Gas: high fire 4.4” W.C. low fire 0.92” W.C.
Meets California and Texas NOx Emission Rules
Heat exchanger: 12 years* for residential and 5 years* for
commercial and hydronic applications; (10 years* if used with the
Rinnai Hydronic Air Handler); all other parts 5 years*; labor 1 year;
(* 3 years if used as a circulating water heater within a circulation
loop, when the water heater is in series with a circulation system
and all circulating water flows through the water heater)
DIMENSIONS
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior
notice. Local, state, provincial and federal codes must be adhered to prior to installation.
Remaining flame (OHS)
Thermal fuse
Automatic frost protection
Back of heater - 0 inches
Bottom of heater - 12 inches
From vent pipe - 0 inches
Back of heater - 0 inches
Bottom of heater - 12 inches
From vent pipe - 0 inches
The wall bracket is adjustable to allow
an additional 1.57 inches (40 mm).
in (mm)
WEIGHT: 50 LBS (23 KG)