Rinnai R63LSE2 Water Heater User Manual


 
VA Series Outdoor LS Manual 3
Specifications
Model R63LSe2 R75LSe R94LSe R98LSe
R98LSe-
ASME
Minimum Gas Consumption Btu/h 15,000 19,000
Maximum Gas Consumption Btu/h 150,000 199,000 180,000 237,000
Hot water capacity (Min - Max) *
0.6 - 6.3 GPM
(2.3 - 24 L/min)
0.6 - 7.5 GPM
(2.3 - 28 L/min) L/min)
0.6 - 9.4 GPM
(2.3 - 35.5
0.6 - 9.8 GPM
(2.3 - 37 L/min)
Hot water capacity, (45ºF rise)
5.5 GPM
(20.8 L/min)
6.6 GPM
(25 L/min)
7.4 GPM
(28 L/min)
8.7 GPM
(33 L/min)
Default Temperature Setting (no controller) 120º F (49º C)
Temperature Controller Default Setting 104º F (40º C)
Maximum Temp Setting (Commercial **) 160º F (71º C) 185º F (85º C)
Maximum Temp Setting (Residential)
Selectable at 120º F (49º C) or at 140º F (60º C) 140º F (60º C)
Minimum Temperature Setting 98º F (37º C)
Weight
46 lb
(21 kg)
55 lb
(25 kg)
Efficiency Rating
Noise level 49 dB (A)
Electrical
Consumption
Normal 45 W 50 W 55 W 72 W
Standby
Anti-frost Protection
100 W 116 W
By-Pass Control Fixed Electronic
Minimum Gas Supply
Pr
see Temperature Ranges for more information
essure
Natural Gas 5.0 inch W.C.
Propane 8.0 inch W.C.
Maximum Gas Supply
Pressure
Natural Gas 10.5 inch W.C.
Propane 13.5 inch W.C.
Type of Appliance Temperature controlled continuous flow gas hot water system.
Operation With or without temperature controls, mounted in kitchen, bathroom, etc.
Approved Gas Type Natural Gas or Propane - Ensure unit matches gas type it's being installed on.
Connections Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT
Ignition System Direct Electronic Ignition
Electric Connections Appliance: AC 120 Volts, 60Hz. Temperature Control: DC 12 Volts (Digital)
Water Temperature Control Simulation Feedforward and Feedback.
Water Supply Pressure Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)
Maximum Water Supply Pressure 150 PSI
Temperature Control Cable Non-Polarized Two Core Cable (Minimum 22 AWG)
2 W
Rinnai is continually updating and improving products. Therefore, specifications are subject to change without
prio
** for commercial and hydronic applications requiring higher temperatures.
r notice.
The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value
listed is for the purpose of input adjustment.
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.
83.0%
Energy Star Qualified No Yes Yes Yes No