Rinnai 16e Water Heater User Manual


 
28
DIP SWITCH SETTING
Dip Switch Positions Explained
OFF ON
SW2 (top)
1 - Gas Type
LEGEND:
2 - Temperature
Black Section indicates
3 - Temperature
position of dip switch.
4 - Temperature
OFF ON
OFF ON
OFF ON
SW1 (bottom)
1 - Computer Programming
2 - Computer Programming OFF ON
3 - Combustion
4 Combustion
Dip Swiches Explained
GAS TYPE
LPG
NAT GAS
OFF ON
SW2
OFF ON
SW2
1 off
1 on
2
2
3
3
4
4
COMPUTER PROGRAMMING
OFF ON
SW1
1 - Switches are always in these
2 - positions for the Infinity 16e.
3
4
COMBUSTION
NORMAL
FORCED LOW FORCED HIGH
OFF ON
SW1
OFF ON
SW1
OFF ON
SW1
1
1
1
2
2
2
3 off
3 on
3 on
4 off
4 off
4 on