Rinnai IB35ETRN Electric Heater User Manual


 
20
• ELECTRIC MOTOR MAINTENANCE
Motors are permanently lubricated and
need no lubrication.
Keep fan and motor free of dust and dirt,
clean annually.
The heater should be serviced
annually only by an authorised person.
• GLASS REPLACEMENT AND
CLEANING. (May be performed by the
owner)
It is best to handle the glass with clean
gloves to avoid smearing the glass with
finger prints which might show after
replacement.
Refer diagram opposite
Open the side panels.(1) Access can now
be obtained to the two top glass retaining
screws.(2)
Gently lift the retaining trim away from the
glass.(3)
Carefully lift the glass out of the bottom
retaining channel, taking care not to
damage the fiber seal on the perimeter of
the glass.(4)
The glass may be cleaned with a damp
sponge and soapy water. If the seal is
damaged it should be replaced. Remove
any soot deposit from the log set with a
soft brush and a vacuum cleaner. Soot
deposit may indicate that the flue is not
drawing properly. Check the flue for correct
operation.
It is best to handle the glass with clean
gloves to avoid smearing the glass with
finger prints which might show after
replacement.
NOTE:
When replacing the glass make sure that
the joint of the fiber seal is at the bottom of
the glass.
BURNERS
Due to the design of the burners in this
heater, they do not require cleaning by the
owner. The burners should be cleaned
once a year by a qualified service agent.
FAN REMOVAL Refer diagram below
NOTE: The fan has a permanently
lubricated bearing. DO NOT OIL.