Riccar RCU-H3 Vacuum Cleaner User Manual


 
11
Installation
(Optional)
1. Insert the rubber coupling on the vacuum air exhausts.
2. Using a Phillips screwdriver, tighten the clamp collar to ensure
adequate sealing.
3. Insert the 90° elbow into the rubber coupling and tighten, then clamp
collar as per instructions in step 2.
4. Apply ABS glue to the 90° elbow and insert mufer.
5. For H11, repeat steps 1 to 4 to install second mufer turned down.
Electric Connections
There should be an electric outlet within 1 meter (3 feet) of your central
vacuum unit. Once the appliance is installed in a suitable location,
connect your central unit to an electric outlet on an dedicated* grounded
circuit. Do not use extension cords or modify the length of your vacuum
cleaner’s power cord.
Dedicated* grounded circuit
North America
120 V / 240 V All models: 15A
Your central vacuum cleaner has a thermal safety device or a circuit breaker
to protect against any over voltage or electrical defect. If that protection
should fail, contact your authorized service center.
*Please reserve a circuit breaker dedicated only to the connections for your
central vacuum.
B
C
D
A
A
A. Rubber coupling
B. 90° elbow
C. Mufer
D. Air Exhaust
Glue not included
If you find that installing your vacuum cleaner is too difficult, ask your service
center to install it for you. When in doubt, it is better to have the work done by a
professional and ensure that the unit is properly installed. Any installation that
does not comply with the specified norms could alter or invalidate the warranty.