These units are designed
to meet or exceed ANSI
(American National
Standards Institute)
requirements and have been
tested according to D.O.E.
test procedures and meet or
exceed the energy efficiency
requirements of NAECA,
ASHRAE standard 90, ICC
Code and all state energy
efficiency performance
criteria for energy consuming
appliances.
Before purchasing this
appliance, read important
energy cost and efficiency
information available from
your supplier.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
G
E
A
B
C
F
D
10"
3/4" N.P.T.
RELIEFVALVE
OPENING
1/2"
EXTERIOR
WALL
(G:
SIDE VENTING
RANGEOF
ADJUSTMENT)
Fury DV
Available in 50 Gallon Gas Model
6-Year Limited Tank Warranty, 1-Year Limited Parts Warranty*
NEW FVIR Compliant!
•
Adjustable coaxial vent allows flexibility
o
f installation – uses outside air for combustion
and requires no electrical power
•
Aluminum vent and cap base to prevent
staining of building exterior
•
Brass drain valve
•
Factory installed temperature and pressure
relief valve
•
R-Foam
®
insulation for superior heat retention
•
Exclusive Rheemglas
®
tank lining resists
corrosion and prolongs tank life
•
Heat saving flue baffle design
•
Gas control and combination thermostat
•
Anode rod equalizes aggressive water action
•
H
igh temperature silicone bands reduce venting
installation time
•
Internal air tube for reduced footprint
•
Meets ANSI Z21.10.1 requirements for
Flammable Vapor Ignition Resistance (FVIR)
•
Meets or exceeds National Appliance Energy
Conservation Act (NAECA) requirements
* See ResidentialWarranty Information Brochureforcomplete
warranty information.
EnergyFactorbasedonD.O.E.(Departmentof Energy)testprocedures.
D
ESCRIPTION FEATURES DIMENSIONS ENERGY INFO.
G
ASINPUTIN RECOVERYIN FIRSTHOUR HT.TO TANK HT.TO VENT HT.TO SHIP. ENERGY
GALLON MODEL THOUS.BTU/HR. G.P.H.90°RISE DEL.G.P.H. VENT HT. DIAMETER GASCONN. SIZE SIDET&P WT. FACTOR
CAPACITY NUMBER
NAT. NAT. NAT.
ABC D E F (LBS)
NAT.
50 RH DV50FV 38 38.4 80 68 59-1/2 21-3/4 14-1/4 6 52-1/2 165 0.58
HOTWATER
CONNECTION
COLD WATER
CONNECTION
ANODE
LONGER VENTING AVAILABLE
Rheem Exclusive Adjustable
Coaxial Vent Allows Flexibility
of Installation…
You may orient the Fury DV
for easiest service
access, because the
adjustable coaxial
vent can swivel
360 degrees.
NEW LONGER VENTING!
• Up to 4 feet above the water heater
and 4 feet from an outside wall.
Order HorizontalVent Kit:
#SP20131
Order VerticalVent Kit:
#SP20132
RH DV50FV
Horizontal
& Vertical
8-1/8 18-1/8 8-1/8 48** 68 – 107†
VENTING – ROUGHING IN DIMENSIONS (INCHES)
MODEL 4FEETVENTING OPTIONALHEIGHT(A)
NUMBER AVAILABLE
MIN. MAX. MIN. MAX.
WITHVENT KIT
SIDEVENTING (G)
WITHINCLUDED
VENTKIT
SIDEVENTING (G)
WITHOPTIONAL
VENTKIT
R
heemglas
®
E
nergy Miser
®
D
irect Vent Gas Water Heaters
n
ow with the Guardian System
™
®
Rheem Manufacturing Company • Water Heater Division
Rheem Canada Ltd./Ltée, 128 Barton Street West, Hamilton, Ontario L8N 3P3
12/07 WP FORM NO. 101-22EFCAN Rev1
** HorizontalVent Kit #SP20131.Venting dimensions are approximate.
† Vertical Vent Kit #SP20132.Venting dimensions are approximate.
• If side wall is combustible material, 1" clearance must be included in adjustment range.