Rheem RJNA Series Electric Heater User Manual


 
Illustration
ST-A0903-01
INTEGRAL POWER EXHAUST FOR ECONOMIZER
(FIELD INSTALLED ONLY)
RXRX-BFF04C—3-5 Ton [10.6-17.6 kW] Models 208-230 V, 1 PH, 60 Hz
For RXRD-KECM3 Economizer
Downflow or horizontal applications
Requires separate power supply with disconnect
Adjustable switch on economizer, factory preset to
energize power exhaust at 95% outside air position
Polarized plug connects power exhaust relay
to economizer
[ ] Designates Metric Conversions
FRESH AIR DAMPER
3 to 5 Ton [10.6 to 17.6 kW] Models
RXRF-FBA1 (Manual)
RXRF-FBB1 (Motorized)
Model No. Volts
RXRX-BFF04C 208-230
No. of Fans
1 1
Phase
240
Watts (ea.)
2600
High Speed
1700 1.06
FLA (ea.)
1.9
LRA (ea.)
CFM
RPM
CFM is at 0" w.c. external static pressure.
POWER EXHAUST KIT FOR RXRD-ECCM(-), RXRD-EECM(-) ECONOMIZERS
FRESH AIR DAMPER
I319.DGN
38
ACCESSORIES