Rheem HE45-160N Water Heater User Manual


 
2
SPECIFICATIONS
DIMENSIONAL INFORMATION
All dimensions shown in English and Metric
MODEL
WATER CONNECTIONS APPROX
NUMBER UNITS
HEIGHT WIDTH DEPTH VENT
INLET OUTLET
SHIPPING WT.
inches 42 23 1/2 32 2 1 1 175 lbs.
mm 1067 597 813 51 25 25 79 kgs
inches 42 23 1/2 32 3 1 1 175 lbs.
mm 1067 597 813 76 25 25 79 kgs
inches 72 23 1/2 32 3* 1-1/2 1-1/2 235 lbs.
mm 1854 597 813 76 38 38 106 kgs
inches 73 27 36 3* 1-1/2 1-1/2 405 lbs.
mm 1854 686 914 76 38 38 184 kgs
All models require a 120V power source.
* 130,000 Btu models are certified to be installed with 2” venting.
HE45-100
HE45-130
HE45-160
HE45-199
HE80-130
HE80-160
HE80-199
HE119-130
HE119-160
HE119-199
RECOVERY CAPACITIES
Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at Various Temperature Rises
MODEL INPUT (BTU/HR) THERMAL
40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F 120°F
NUMBER NAT. & LP EFFICIENCY UNITS
(22.2°C) (27.8°C) (33.3°C) (38.9°C) (44.4°C) (50.0°C) (55.6°C) (61.1°C) (66.7°C)
100,000 95%
GPH 288 230 192 165 144 128 115 105 96
LPH 1090 872 726 623 545 484 436 396 363
130,000 95%
GPH 374 299 249 214 187 166 150 136 125
LPH 1417 1133 944 809 708 630 567 515 472
160,000 95%
GPH 461 368 307 263 230 205 184 167 154
LPH 1744 1395 1162 996 872 775 697 634 581
199,000 95%
GPH 573 458 382 327 286 255 229 208 191
LPH 2169 1735 1446 1239 1084 964 867 789 723
Recovery rating is based on thermal efficiencies obtained in an AGA certified laboratory.
0" CLEARANCE TO
COMBUSTIBLES ON ALL
ADVANTAGE PLUS UNITS,
HOWEVER, A 24"
CONTROL PANEL SER-
VICE CLEARANCE IS
RECOMMENDED.
HE45-100
HE45-130
HE80-130
HE119-130
HE80-160
HE119-160
HE80-199
HE119-199
BOOSTER MODELS
Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH)
MODEL INPUT (BTU/HR) THERMAL
40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F
NUMBER NAT. & LP EFFICIENCY UNITS
(22.2°C) (27.8°C) (33.3°C) (38.9°C) (44.4°C) (50.0°C) (55.6°C) (61.1°C) (66.7°C) (72.2°C) (77.8°C)
HE45-160 160,000 95%
GPH 461 368 307 263 230 205 184 167 154 142 132
LPH 1744 1395 1162 996 872 775 697 634 581 536 498
HE45-199 199,000 95%
GPH 573 458 382 327 286 255 229 208 191 176 164
LPH 2169 1735 1446 1239 1084 964 867 789 723 667 620
All models exceed the minimum NAECA energy efficiency requirements of ASHRAE 90.1b-1989, 1992 requirements.
MAXIMUM DELIVERY
In U.S. Gallons and Liters
(Includes useable storage and recovery for indicated times)
MODEL
GALLONS/
MAX.
INPUT (BTU/HR)
TEMP. 5 10 15 20 30 45 1 2 3 MIN. TO RECOVER
NUMBER
LITERS
SETPOINT
NAT. & LP
RISE UNITS MIN. MIN. MIN. MIN. MIN. MIN. HR. HR. HR. CONTENTS
HE45-100
45
160º 100,000
100°F GAL. 41 51 60 70 89 118 147 262 377
23
170 55.6°C LTR. 156 192 228 265 337 446 555 991 1427
HE45-130
45
160º 130,000
100°F GAL. 44 56 69 81 106 144 181 331 481
18
170 55.6°C LTR. 166 214 261 308 403 544 686 1253 1819
HE80-130
80
160º 130,000
100°F GAL. 68 81 93 106 131 168 206 355 505
32
303 55.6°C LTR. 259 306 354 401 495 637 779 1345 1912
HE119-130
119
160º 130,000
100°F GAL. 96 108 121 133 158 196 233 383 532
48
450 55.6°C LTR. 363 410 457 504 599 750 882 1449 2015
HE45-160
45
180º* 160,000
100°F GAL. 47 62 78 93 124 170 216 400 584
15
170 55.6°C LTR. 177 235 294 352 468 642 817 1514 2211
HE80-160
80
160º 160,000
100°F GAL. 71 87 102 117 148 194 240 424 609
26
303 55.6°C LTR. 270 328 386 444 561 735 909 1607 2304
HE119-160
119
160º 160,000
100°F GAL. 99 114 129 145 175 221 268 452 636
39
450 55.6°C LTR. 373 432 490 548 664 838 1013 1710 2408
HE45-199
45
180º* 199,000
100°F GAL. 51 70 89 108 146 203 261 490 719
12
170 55.6°C LTR. 192 264 336 408 553 770 987 1854 2721
HE80-199
80
160º 199,000
100°F GAL. 75 94 113 132 171 228 285 514 743
21
303 55.6°C LTR. 284 357 429 501 646 863 1079 1947 2814
HE119-199
119
160º 199,000
100°F
GAL. 102 121 141 160 198 255 312 542 771
31
450 55.6°C LTR. 338 460 532 604 749 966 1183 2050 2918
All models have a maximum setpoint of 160°F with the exception of the HE45-160 and HE45-199 booster models. The HE45-160 and HE45-199 have a maximum setpoint of 180°F.
* NOTE: The 180º F models are shipped with all necessary components for an approved installation (see Booster Installation Kit for component list.)