Power Vent Kits continued.
Vent Kits
Kit # Part # Applicable Rheem-Ruud Water Heater Model
PV Kit 4 AP11646 G50-98, G75-125, G82-156, G76-180
PV Kit 5 AP11645 G37-200, G76-200, G91-200, G100-200(A), G72-250(A), G100-250(A), G100-270(A),
G72-300(A),G85-300(A), G100-310(A), G65-360(A), G65-400(A), G85-400(A), G100-400(A)
Dimensions
Power Venter
(from Tjernlund)
Motor Motor Max Height Width Depth Inlet
Kit# Watts Amps Vent (H) (W) (D) Outlet
4 95 1.26 50 ft 7-7/8" 11" 7" 4"
5 170 1.51 50 ft 9-1/4" 11-5/8" 8-5/8" 6"
Note: Max Vent Length based on total length of straight vent pipe plus 10
feet for each 90 degree elbow and 5 feet for each 45 degree elbow.
H
D
W
Vent Terminal
Rough in
Kit#
AB CDimension
4 9" 9-1/2" 7" Sq. 8" Sq.
5 10-1/8" 9-1/2" 8-1/2" Dia. 9" Dia.
A Sq.
C
B
Floor
Exterior
Wall
Typical
Application
Draft
Vent Hood Vent Vent
Model Kit Outlet Size Adapter*
G50-98 PV Kit 4 5" 4" 5" x 4"
G75-125 PV Kit 4 5" 4" 5" x 4"
G82-156 PV Kit 4 6" 4" 6" x 4"
G76-180 PV Kit 4 6" 4" 6" x 4"
G37-200 PV Kit 5 6" 6" Not Required
G76-200 PV Kit 5 6" 6" Not Required
G91-200 PV Kit 5 6" 6"
Not Required
G100-200(A) PV Kit 5 6" 6" Not Required
G72-250(A) PV Kit 5 6" 6" Not Required
G100-250(A) PV Kit 5 6" 6"
Not Required
G100-270(A) PV Kit 5 6" 6" Not Required
G72-300(A) PV Kit 5 8" 6" 8" x 6"
G85-300(A) PV Kit 5 8" 6" 8" x 6"
G100-310(A) PV Kit 5 7" 6" 7" x 6"
G65-360(A) PV Kit 5 8" 6" 8" x 6"
G65-400(A) PV Kit 5 8" 6" 8" x 6"
G85-400(A) PV Kit 5 10" 6" 10" x 6"
G100-400(A) PV Kit 5 8" 6" 8" x 6"
*Note: Vent Pipe and Vent Adapter are NOT included.