Rheem Commercial Booster Water Heater User Manual


 
TABLE B – RECOVERY CAPACITIES
Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at Various Temperature Rises
INPUT EQUIVALENT 40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F
KW BTU/HR. UNITS (22°C) (28°C) (33°C) (39°C) (45°C) (50°C) (56°C) (61°C) (67°C) (72°C) (78°C)
6 20,473 GPH 62 50 41 35 31 28 25 23 21 19 18
LPH 235 188 157 134 117 104 94 85 78 72 67
9 30,710 GPH 93 74 62 53 47 41 37 34 31 29 27
LPH 352 282 235 201 176 157 141 128 117 108 101
12 40,946 GPH 124 99 83 71 62 55 50 45 41 38 35
LPH 470 376 313 268 235 209 188 171 157 145 134
15 51,183 GPH 155 124 103 89 78 69 62 56 52 48 44
LPH 587 470 391 335 294 261 235 213 196 181 168
18 61,420 GPH 186 149 124 106 93 83 74 68 62 57 53
LPH 705 564 470 403 352 313 282 256 235 217 201
TABLE A – ELECTRICAL CHARACTERISTICS
6 3 2000 29 17 25 14 6 2 2 2 1
9 3 3000 43 25 38 22 9 6 3 2 1
12 3 4000 58 33 50 29 12 6 3 2 1
15 3 5000 72 42 63 36 15 6 3 2 1
18 3 6000 87 50 75 43 18 6 3 2 1
INPUT
KW
NUMBER
OF
ELEMENTS
ELEMENT
WATTAGE
FULL LOAD CURRENT
IN AMPERES
208V
PHASE
1 3
240V
PHASE
1 3
600
PHASE
3
NUMBER
OF CONTRACTORS
208/240V 600V
NUMBER
OF FUSES
30A CLASS G
208/240V 600V
OPTIONAL THERMOSTATS
(EGF MODELS ONLY)
THERMOSTAT
TEMPERATURE
LIMIT CONTROL
ELEMENT AND
CLEANOUT
ACCESS PANEL
CONTROL
CENTER
HINGED DOOR
1
1
/
4
" HOT
OUTLET
NIPPLE
1
1
/
4
" COLD
INLET
NIPPLE
21
1
/
2
"
21
3
/
4
"
8
1
/
4
"
4
3
/
4
"
5
3
/
4
"
6"
13
3
/
4
"
17"
INLET
OUTLET
CONTACTORS
APPROXIMATE WEIGHT 110 LBS.
NSF LABEL
DRAIN
VALVE
TRANSFORMER
TERMINAL
BLOCK
FUSE BLOCKS (FUSED MODELS ONLY)
3
/
4
" T&P FEMALE
VALVE TAPPING