Rheem Manufacturing Company 3
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONS
MODEL NUMBERS
RGLH- SERIES
05EAUER
05NAUER
07EAUER
07NAUER
Standard Filter [mm]
(1) 14 x 20
[356 x 508]
(2) 12 x 20
[305 x 508]
Input–BTU/Hr [kW] ➁
50,000 [15] 75,000 [22]
Heating Capacity BTU/Hr [kW] ➀
41,000 [12] 60,000 [18]
High Altitude Input [kW] 45,000 [13] 67,500 [19.8]
Blower (D x W) [mm]
11 x 6
[279 x 152]
11 x 6
[279 x 152]
Motor H.P. [W]–Speeds [W]–
PSC Type
1
/2-4-PSC
[373]
1
/2-4-PSC
[373]
Motor Full Load Amps 6.8 7.1
Heating Speed MED-LOW MED-HIGH
Cooling Speed HIGH HIGH
Cooling CFM @ .5" [kPa] E.S.P.
(Nominal) [L/s]
1200
[566]
1200
[566]
Rated E.S.P. (In. W.C.) [kPa] .50 [.12] .50 [.12]
Temperature Rise Range °F
[°C]
25-55
[13.9-30.6]
40-70
[22.2-38.9]
Max. Outlet Air Temp. °F
[°C]
155
[68.3]
165
[73.9]
Approx. Shipping Weight (Lbs.)
[kg]
85
[38.6]
105
[47.6]
California Seasonal Efficiency–
Electric Ignition No
x
Models
75.9/76.2 74.4/74.9
High Altitude Output
Capacity [kW]
36,500 [10.7] 53,500 [15.7]
Heat Ext. Static Pressure [kPa] .10 [.025] .12 [.029]
07EAMGR
07NAMGR
10EAMER
10NAMER
10EBRJR
10NBRJR
12EARJR
12NARJR
(2) 12 x 20
[305 x 508]
(2) 12 x 20
[305 x 508]
(2) 14 x 20
[356 x 508]
(2) 14 x 20
[356 x 508]
75,000 [22] 100,000 [29.3] 100,000 [29.3] 125,000 [36.6]
54,000 [15.8] 72,000 [21.1] 72,500 [21.2] 89,000 [26.1]
60,500 [18] 80,000 [23] 81,000 [24] 99,000 [29]
.12 [.029] .15 [.037] .15 [.037] .20 [.05]
67,500 [19.8] 90,000 [26.4] 90,000 [26.4] 112,500 [33]
11 x 7
[279 x 178]
11 x 6 = 10*AU
[279 x 152]
11 x 7 = 10*AM
[279 x 178
11 x 10
[279 x 254]
11 x 10
[279 x 254]
3
/4-4-PSC
[559]
1
/2-4-PSC
[373]
3
/4-4-PSC
[559]
3
/4-4-PSC
[559]
9.5 7.1 9.5 9.5
MED-LOW MED-HIGH MED-LOW MED-LOW
MED-HIGH HIGH MED-HIGH MED-HIGH
1600
[755]
1200
[566]
2000
[944]
2000
[944]
.50 [.12] .50 [.12] .50 [.12] .50 [.12]
25-55
[13.9-30.6]
55-85 = 10*AU
[30.6-47.2]
45-75 = 10*AM
[25-41.7]
40-70
[22.2-38.9]
40-70
[22.2-38.9]
155
[68.3]
190
[87.8]
190
[87.8]
180
[82.2]
105
[47.6]
115
[52.2]
120
[54.4]
140
[63.5]
75.1/75.5 75.2/75.2 74.7/74.7 75.2/75.3
15EARJR
15NARJR
(2) 14 x 20
[356 x 508]
150,000 [44]
107,500 [31.5]
120,000 [35]
.20 [.05]
135,000 [39.6]
11 x 10
[279 x 254]
3
/4-4-PSC
[559]
9.5
MED-LOW
MED-HIGH
2000
[944]
.50 [.12]
50-80
[27.8-44.4]
190
[87.8]
150
[68.0]
76.0/75.9
81.1% 80.2% 80% 80%
AFUE–Electric Ignition Models ➀
82.2% 80.5% 80%
NOTES: All models are 115V, 60HZ, 1
Ø
. Gas connection size for all models is
1
/2" N.P.T.
➀ In accordance with D.O.E. test procedures.
➁ See Conversion Kit Index Form No. 92-21519-52 for U.S. models and Form No. 92-21519-53 for Canadian models for high altitude derate.
MODEL IDENTIFICATION—DOWNFLOW MODELS
[ ] Designates Metric Conversions
R G L H
—
A U E R
Rheem Gas Downflow Design Variations Blower Heating & Cooling Fuel Type
U = 11 x 6
[279 x 152 mm]
M = 11 x 7
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
S = 500-1200 CFM
[236-566 L/s]
E =1100-1330 CFM
[519-628 L/s]
G= 1450-1750 CFM
[684-826 L/s]
J = 1800-2075 CFM
[850-979 L/s]
Furnace Series A = Std.
Cabinet
B = Wide
Cabinet
Designation Designation R = Natural Gas,
U.S. and
Canadian
Standard
Furnace
NO
x
Model
05N
07N
10N
12N
15N
Input
BTU/HR
50,000 [15 kW]
75,000 [22 kW]
100,000 [29 kW]
125,000 [37 kW]
150,000 [44 kW]
Electric
Ignition
05E
07E
10E
12E
15E
Heating Input Designation
07E