15
102961
REMJ70 REMJ150
Heat Output
(Kcal/hr) 17,640 38,500
Fuel Consumption
(liters/hr) 1.9 4.2
Fuel Tank Capacity
(liters) 16 47
Run Time per Tank
(hours) 8 11
Hot Air Output
(m
3
/min) 6.7@50Hz 12.4@50Hz
7.5@60Hz 13.7@60Hz
Voltage 100 100
Frequency (Hz) 50/60 50/60
Wattage (W) 200 340
Pump Pressure
(kg/cm
2
) 0.35@50Hz 0.35@50Hz
0.38@60Hz 0.37@60Hz
(PSI) 5.0@50Hz 5.0@50Hz
5.4@60Hz 5.3@60Hz
Fan
IMPORTANT:
Remove fan
from motor shaft before
removing motor from heater.
The weight of the motor
resting on the fan could
damage the fan pitch.
1. Remove upper shell (see
page 10).
2. Use 1/8" allen wrench to
loosen setscrew which
holds fan to motor shaft.
3. Slip fan off motor shaft.
4. Clean fan using a soft cloth
moistened with kerosene or
solvent.
5. Dry fan thoroughly.
6. Replace fan on motor
shaft. Place fan hub flush
with end of motor shaft
(see Figure 24).
7. Place setscrew on flat of
shaft. Tighten setscrew
firmly (40-50 inch-pounds/
4.5-5.6 n-m).
8. Replace fan guard and
upper shell.
SPECIFICATIONS
Figure 24 - Fan Cross Section
Setscrew
Motor
Shaft
Fan
Flush
Motor
Shaft
Setscrew
Fan
Figure 23 - Fan, Motor Shaft, and Setscrew Location