CLEANING AND MAINTENANCE
ODS/Pilot and Burner
Cleaning Burner Pilot Air Inlet
Cabinet
CABINET
Air Passageways
Use a vacuum cleaner or pressurized air to clean.
Exterior
Use a soft cloth dampened with a mild soap and water mixture.
Wipe the cabinet to remove dust.
Figure 22 - Pilot Inlet Air Hole
Pilot Assembly
Pilot Air Inlet
Hole
CLEANING AND
MAINTENANCE
ODS/PILOT AND BURNER
Use a vacuum cleaner, pressurized air, or small, soft bristled
brush to clean.
CLEANING BURNER PILOT AIR INLET
The primary air inlet holes allow the proper amount of air to mix with
the gas. This provides a clean burning flame. Keep these holes clear
of dust, dirt, and lint. Clean these air inlet holes prior to each heating
season. Blocked air holes will create soot. We recommend that you
clean the unit every three months during operation and have heater
inspected yearly by a qualified service person.
We also recommend that you keep the burner tube and pilot
assembly clean and free of dust and dirt. To clean these parts we
recommend using compressed air no greater than 30 PSI. Your local
computer store, hardware store, or home center may carry com-
pressed air in a can. You can use a vacuum cleaner in the blow
position. If using compressed air in a can, please follow the direc-
tions on the can. If you don't follow directions on the can, you could
damage the pilot assembly.
1. Shut off the unit, including the pilot. Allow the unit to cool for
at least thirty minutes.
2. Inspect burner, pilot for dust and dirt.
3. Blow air through the ports/slots and holes in the burner.
4. Never insert objects into the pilot tube.
Clean the pilot assembly also. A yellow tip on the pilot flame
indicates dust and dirt in the pilot assembly. There is a small pilot
air inlet about two inches from where the pilot flame comes out of
the pilot assembly (see Figure 22). With the unit off, lightly blow air
through the air inlet. You may blow through a drinking straw if
compressed air is not available.
WARNING: Turn off heater and let cool before
cleaning.
CAUTION: You must keep control areas, burner,
and circulating air passageways of heater clean.
Inspect these areas of heater before each use. Have
heater inspected yearly by a qualified service person.
CAUTION: You must check and keep burner/
venturi tubes clean of insect and insect nest. A
clogged tube can lead to a fire.
(Propane/LP
Pilot Shown)
Pilot Assembly
Pilot Air Inlet
Figure 23 - Injector Holder On Burner Tube
Burner
Tube
Injector Holder
Ports/Slots