Regency Wraps U38-LP1 Stove User Manual


 
Regency
®
U38-1 ULTIMATE Freestanding Gas Stove
19
OPERATING INSTRUCTIONS
2) Push in PILOT knob slightly and turn clock-
wise to off. Knob cannot be turned from
pilot to off unless knob is pushed in slightly.
Do not force.
3) Wait ve minutes to allow gas, that may have
accumulated in the main burner compart-
ment, to escape. If you smell gas, follow the
instructions on the front of this manual. If
you don't smell gas continue on to the next
step.
4) Turn the PILOT knob counterclockwise to
pilot and align it with the arrow as shown
in diagram 1.
5) Push in PILOT knob all the way in and hold.
Immediately push IGNITOR button until pilot
lights. Continue to hold the PILOT knob in
for approximately one minute, then release
the PILOT knob. The pilot fl ame should
continue to burn. If the pilot does not remain
lit, repeat operation allowing a longer period
before releasing PILOT knob.
6) Turn PILOT knob counter clockwise to
on.
7) Use the Burner ON/OFF switch to turn on
the burner.
8) Rotate the HEAT control to adjust the fl ame
height higher or lower.
SHUTDOWN
INSTRUCTIONS
1) Use the Burner ON/OFF switch, thermostat
or remote control to turn off the burner.
2) Push in the PILOT knob slightly and turn
clockwise to off. Do not force.
3) Turn off all electric power to the appliance
if service is to be performed.
FIRST FIRE
The FIRST FIRE in your stove is part of the
paint curing process. To ensure that the paint
is properly cured, it is recommended that you
burn your fi replace for at least four (4) hours
the fi rst time you use it with the fan on. When
fi rst operated, the unit will release an odour
caused by the curing of the paint and the burn-
OPERATING
INSTRUCTIONS
Before operating this appliance, proceed through
the following check list.
1) Read and understand these Instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the three pieces of door glass
are properly positioned. Never operate the
appliance with any of the glass removed or
with the door open.
5) Verify that all venting and the cap is unob-
structed.
6) Verify log placement. If the pilot cannot be
seen when lighting the unit - the logs or the
embers have been incorrectly positioned.
7) The unit should never to turned off and on
without a minimum of a 60 second wait.
LIGHTING
INSTRUCTIONS
NOTE: For all propane units and units
equipped with electric spark boxes, see
"Copy of Lighting Plate Instructions" sec-
tion for more details.
IMPORTANT: The PILOT knob cannot be
turned from pilot to off unless it is partially
depressed.
Note: Open the pedestal door of the unit
before lighting the pilot. Once the
pilot is lit, close the door. You should
never operate the unit with the door
open.
Diagram 1
1) If the PILOT knob is in the off position proceed
to Step 4.
ing off of any oils remaining from manufactur-
ing. Smoke detectors in the house may go off
at this time. Open a few windows to ventilate
the room for a couple of hours. The glass may
require cleaning.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS STILL HOT!
Note: When the glass is cold and the appli-
ance is lit, it may cause condensation
and fog the glass. This condensation
is normal and will disappear in a few
minutes as the glass heats up.
DO NOT BURN THE APPLIANCE WITH-
OUT THE GLASS FRONT IN PLACE.
AUTOMATIC
CONVECTION FAN
OPERATION
The fan operates automatically - turn the knob
on the pedestal control panel to adjust to the
desired speed. The fan will turn on as the stove
comes up to operating temperature. After the
unit has been turned off and cools to below a
useful heat output range the fan will shut off
automatically.
ADJUSTING FLAME
HEIGHT
Your heater has an adjustable fl ame to tailor the
look and heat output to your specifi c needs. It
is adjusted by turning the fl ame adjustment dial
on the gas control valve.
Turn clockwise to
adjust the flame
higher, counter-
clockwise for a
lower fl ame.