Regency Wraps F2400M Stove User Manual


 
Regency Freestanding Woodstove
16
Slide the tube into the left hand side, as far
as possible and then bring it back into the
hole on the right hand side until it locks into
position. If the tube will not slide in easily,
simply use a pair of vise grips or pliers and
tap it into place with a hammer. A tighter fi t
will ensure the tube will not move when the
unit is burning.
2) Slide the left baffl e over the air tubes from
the front and then push it to the back.
SIMPSON DURA-PLUS
Qty.Part # Description
1 6DVL8693 Connector Kit
1 6DP-MH9096 Mobile Home Kit
ICC EXCEL 2100
Qty.Part # Description
1 6CL48 48" Chimney length (also in
12", 18", 24" lengths.
1 6RC Rain Cap
1 6RCS Spark Screen (for rain cap)
1 6RDS/SQS Round/Square support box
1 6VF Flashing
1 6UBA "Ultrablack" Close Clearance
Connector
Canadian Installations*
SECURITY S2100 (see above for details)
ICC EXCEL 2100 (see above for details)
SELKIRK SENTINAL CF
*The use of alternate pitch fl ashings, support
box extensions, additional chimney lengths,
and additional chimney bracing, may be used
on each of the previously listed systems. These
parts though must be from the same system
as listed, and must be a similar and/or compli-
mentary part.
CAUTION: At no time use unlabelled
parts, or substitute parts made for
another chimney system.
Install as per chimney manufacturer's instal-
lation instructions.
FLUE BAFFLE &
SECONDARY AIR TUBE
INSTALLATION
The fl ue baffl e system located in the upper area
of the fi rebox is removable to make cleaning
your chimney system easier. The baffl es must
be installed prior to your fi rst fi re. Smoke
spillage and draft problems may occur if
the baffl es are improperly positioned. Check
the position of the baffl es on a regular basis as
they can be dislodged if too much fuel is forced
into the fi rebox.
Freestanding Stove
F2400M
The unit arrives with the 2 baffl es on the fl oor
of the fi rebox.
1) If all 4 air tubes are installed continue on to
Step 2), if not, follow the instructions below.
Install the air tube into the holes in the side
channels. The notch goes on the right hand
side with the air holes facing toward the door.
LISTED COMPONENTS
FOR MOBILE HOME
INSTALLATION
The Regency F2400M and S2400M Freestand-
ing pedestal units are approved for installation
in a Mobile Home if one of the following pipe
systems is used.
U.S. Installation*
METALBESTOS SSII
Qty. Part # Description
1 6DS-VK Connector Kit
1 6TMH Shield/Support
1 6TAF-6 Flashing
1 6T-36 Chimney Length
1 6T-18 Chimney Length
1 6T-CT Rain Cap
PRO-JET 3103
Qty.Part # Description
1 PV06-TK Connector
1 CSB Shield/Support
1 RRS Radiation Shield
1 LFR03 Flashing
1 SL3 Chimney Length
1 SL1 Chimney Length
1 RCSA Rain Cap
SECURITY ASHT
Qty.Part # Description
1 DL42A-6 Connector Kit
1 6SS Shield/Support
1 6FAMH Flashing
1 6L3 Chimney Length
1 6L1 Chimney Length
1 CPE Rain Cap
SECURITY S2100
Qty.Part # Description
1 DL42A-6 Connector Kit
1 6XSF Support
1 6XFA Flashing
1 6XL3 Chimney Length
1 6XL18 Chimney Length
1 6XCPE Rain Cap
METAL-FAB TEMP/GUARD 2100
Qty.Part # Description
1 6DWBK Connector
1 6TGRS Roof Support
1 6TGG36 Chimney Length
1 6TGG12 Chimney Length
1 6TGF Flashing
1 6TGC Rain Cap
AMERI-TEC HS
Qty.Part # Description
1 6DCC Connector
1 6HSRS-12 Roof Support
(6PLRS-12-BK)
1 6F Flashing
1 6HS-36 Chimney Length
1 6HS-18 Chimney Length
1 6HS-RCS Rain Cap (6PL-MPC)
INSTALLATION
3) Tilt the left baffl e up on top of the side chan-
nel and it will leave enough room to position
the right baffl e in the same manner as Step
1) above. Then reposition the left baffl e fl at
on the air tubes.
4) Important: push both baffl es so they are
tight against the side walls.
Note: When getting the chimney cleaned,
push the baffl es forward toward the
front of the stove, this should leave
suffi cient access to the fl ue. If it is
not enough space then remove the
middle air tube (reverse the procedure
in step 1) above), and baffl e and then
replace everything when cleaning is
completed.
Side View
Front View
Front View