OPERATING INSTRUCTIONS
3) Wait five minutes to allow gas, that may
have accumulated in the main burner com-
partment, to escape. If you smell gas, fol-
low the instructions on the front of this
manual. If you don't smell gas continue on
to the next step.
4) Turn the PILOT knob counterclockwise to
pilot and align it with the arrow as shown
in diagram 1.
5) Push in PILOT knob all the way in and hold.
Immediately push IGNITOR button until pilot
lights. Continue to hold the PILOT knob in for
approximately one minute, then release the
PILOT knob. The pilot flame should continue
to burn. If the pilot does not remain lit, repeat
operation allowing a longer period before
releasing PILOT knob.
6) Turn PILOT knob counter clockwise to on.
7) Use the Burner ON/OFF switch to turn on
the burner.
8) Rotate the HEAT control to adjust the flame
height higher or lower.
SHUTDOWN
INSTRUCTIONS
1) Use the Burner ON/OFF switch, thermostat
or remote control to turn off the burner.
2) Push in the PILOT knob slightly and turn
clockwise to off. Do not force.
3) Turn off all electric power to the appliance
if service is to be performed.
FIRST FIRE
The FIRST FIRE in your stove is part of the paint
curing process. To ensure that the paint is
properly cured, it is recommended that you
burn your fireplace for at least four (4) hours
the first time you use it with the fan on. When
first operated, the unit will release an odour
caused by the curing of the paint and the
burning off of any oils remaining from manufac-
turing. Smoke detectors in the house may go off
at this time. Open a few windows to ventilate
the room for a couple of hours. The glass may
require cleaning.
OPERATING
INSTRUCTIONS
Before operating this appliance, proceed
through the following check list.
1) Read and understand these Instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the three pieces of door glass
are properly positioned. Never operate the
appliance with any of the glass removed or
with the door open.
5) Verify that all venting and the cap is unob-
structed.
6) Verify log placement. If the pilot cannot be
seen when lighting the unit - the logs or the
embers have been incorrectly positioned.
7) The unit should never to turned off and on
without a minimum of a 60 second wait.
LIGHTING
INSTRUCTIONS
IMPORTANT: The PILOT knob cannot be
turned from pilot to off unless it is partial-
ly depressed.
Note: Open the pedestal door of the unit
before lighting the pilot. Once the
pilot is lit, close the door. You
should never operate the unit with
the door open.
1) If the PILOT knob is in the off position
proceed to Step 4.
Diagram 1
2) Push in PILOT knob slightly and turn clock-
wise to off. Knob cannot be turned from
pilot to off unless knob is pushed in slight-
ly. Do not force.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS STILL HOT!
Note: When the glass is cold and the
appliance is lit, it may cause con-
densation and fog the glass. This
condensation is normal and will
disappear in a few minutes as the
glass heats up.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
AUTOMATIC
CONVECTION FAN
OPERATION
The fan operates automatically - turn the knob
on the pedestal control panel to adjust to the
desired speed. The fan will turn on as the stove
comes up to operating temperature. After the
unit has been turned off and cools to below a
useful heat output range the fan will shut off
automatically.
ADJUSTING FLAME
HEIGHT
Your heater has an adjustable flame to tailor the
look and heat output to your specific needs. It
is adjusted by turning the flame adjustment dial
on the gas control valve.
Turn clockwise to
adjust the flame
higher, counter-
clockwise for a
lower flame.