U37-1 Regency
®
ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove 27
MAINTENANCE
MAINTENANCE
INSTRUCTIONS
1) Always turn off the valve before cleaning.
For relighting, refer to lighting instructions.
Keep the burner and control compartment
clean by brushing and vacuuming at least
once a year. When cleaning the logs, use a
soft clean paint brush as the logs are fragile
and easily damaged.
2) Clean glass (never when unit is hot), appli-
ance, louvers, and door with a damp cloth.
Never use an abrasive cleaner. The gold
louvers (and optional gold door) may be
scratched if abrasives are used to clean
them.
The heater is fi nished in a heat resistant
paint and should only be refi nished with
heat resistant paint (not with wall paint).
Regency
®
uses StoveBright Paint - Metallic
Black #6309.
3) Make a periodic check of burner for proper
position and condition. Visually check the
fl ame of the burner periodically, making sure
the fl ames are steady; not lifting or fl oating.
If there is a problem, call a qualifi ed service
person.
4) The appliance and venting system must be
inspected before use, and at least annually,
by a qualifi ed fi eld service person, to ensure
that the fl ow of combustion and ventilation
air is not obstructed.
During the annual service call, the burners
should be removed from the burner tray
and cleaned. Replace the embers but do
not block the pilot.
5) Keep the area near the appliance clear and
free from combustible materials, gasoline,
and other fl ammable vapours and liquids.
Top View of pilot fl ame
GENERAL
VENT MAINTENANCE
Conduct an inspection of the venting system
semi-annually. Recommended areas to inspect
as follows:
1) Check the Venting System for corrosion in
areas that are exposed to the elements.
These will appear as rust spots or streaks,
and in extreme cases, holes. These com-
ponents should be replaced immediately.
2) Check for evidences of excessive condensa-
tion, such as water droplets forming in the
inner liner, and subsequently dripping out the
joints, Continuous condensation can cause
corrosion of caps, pipe, and fi ttings. It may
be caused by having exterior portions of the
system being exposed to cold weather.
3) Inspect joints, to verify that no pipe sec-
tions or fi ttings have been disturbed, and
consequently loosened.
LOG REPLACEMENT
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door to carefully remove the
logs. The pilot light generates enough heat to
burn someone. If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagram under Log
Installation.
Note: Improper positioning of logs may
create carbon build-up and will alter
the unit’s performance which is not
covered under warranty.
GOLD-PLATED DOORS
The 24 carat gold plated fi nish on the door
requires little maintenance, and need only be
cleaned with a damp cloth. DO NOT use abrasive
materials or chemical cleaners, as they may
harm the fi nish and void the warranty. Clean any
fi ngerprints off before turning the unit on. If the
door starts to discolour, check the gasket
seal and replace if necessary.
DOOR GASKET
If the door gasket requires replacement use
7/8" diameter oval door gasket (Part # 650-
920).
Top View of pilot fl ame
Incorrect fl ame pattern will have small, probably
yellow fl ames, not coming into proper contact
with the rear of the burner or thermopile.
6) Each time the appliance is lit, it may cause
condensation and fog the glass. This
condensation and fog is normal and will
disappear in a few minutes as the glass
heats up.
Never operate the appliance without the
glass properly secured in place or with
the door open.
7) Periodically check the pilot fl ames. Correct
fl ame pattern has three strong blue fl ames:
1 fl owing around the thermopile and 1
around the thermocouple, and 1 fl owing
across the rear of the burner (it does not
have to be touching the burner).
Note: If you have an incorrect fl ame pat-
tern, contact your Regency
®
dealer
for further instructions.
PART OF CONTROL SYSTEM AND
ANY GAS CONTROL WHICH HAS
BEEN UNDER WATER.
CAUTION: ANY SAFETY SCREEN
OR GUARD REMOVED FOR SERV-
ICING AN APPLIANCE MUST BE
REPLACED PRIOR TO OPERAT-
ING THE APPLIANCE.
CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD NOT
BE PLACED ON OR NEAR THE
APPLIANCE.
WARNING: CHILDREN AND
ADULTS SHOULD BE ALERTED
TO THE HAZARDS OF HIGH
SURFACE TEMPERATURE AND
SHOULD STAY AWAY TO AVOID
BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM
AS THE APPLIANCE.
DO NOT USE THIS APPLIANCE
IF ANY PART HAS BEEN UNDER
WATER. IMMEDIATELY CALL A
QUALIFIED SERVICE TECHNI-
CIAN TO INSPECT THE APPLI-
ANCE AND TO REPLACE ANY