Regency R90 Indoor Fireplace User Manual


 
173June 2007 Regency Product Specifi cations Book
Wood Fireplaces
Wood Fireplaces
Gravity Air Feed Kit Option
The Gravity Air Feed Kit is designed to extend the heat output vent above
the R90 to the front or the side. The upper louver opening is blocked off
and fl ex vent is connected to the vent holes in the top of the unit and
run to discharge vent grilles. Both 8" (203mm) diameter insulated Flex
vents must be used along with one 30 sq. inch (194cm
2
) chase vent grill
to bring additional air into the chase (for U.S. installations only).
Qty Description
4 Connector Collars
4 Adjustable Clamps
2 5’ lengths of fl exible vent pipe (8” dia.)
2 Insulated Sleeves
1 Block Off Plate
2 Discharge Vent Mounting Frames
7 1/4-20 x 1/2” Truss Head Screws (used for EX90/R90 only)
2 16 x 8 Discharge Vent Grilles
4 #8 Drywall Anchors
4 Insulation Strips
1 Chase Vent Frame (for U.S. installations only)
1 8 x 8 Chase Vent Grille (for U.S. installations only)
Discharge Vent
Grill
Chase Vent
Grill
30 sq.in. (194 sq.cm)
opening
Alternate Position for
Chase Vent Grill
Block-off Plate
(replace top louver)
Base of Stove
Vent Cover 'B'
(Inside)
Vent Cover 'A"
Center-line
of Vent
6" (152mm) Min.
To Rouch Opening
Ceiling
Flue
Flex Vent
Clamp
Connector
Collar
Connector
Collar
Outside Air
Intake
Insulation
Strips
R90 Wood FireplaceR90 Wood Fireplace
Flex Vent
Discharge
Vent Grille
Discharge Vent
Frame
Connecting
Collar
Clamp
Flex
Vent
Insulation
Strips
1) Remove the screw from the vent hole cover (vent cover 'A') on top
of the unit.
2) Take the connector collar and press and rotate it into the hole to
cut through the insulation layer. Remove the collar and remove
insulation from the collar. The screws for the inner cover should
be exposed.
3) Remove the screws from the inner cover (vent cover 'B') and slide
it back under the insulation.
4) Extend ex vent and pull the insulation sleeves over the 8” (203mm)
diameter fl ex vents. Leave a short section of fl ex vent exposed at
each end. On one end insert the collar into the fl ex vent and use
a clamp to hold the fl ex vent in place.
5) Use tin snips to cut slits into the rim of the connector collar. A
minimum of four tabs will be required so cut the slits 1” (25mm) (i.e.
1” (25mm) wide tabs) apart around the perimeter of the collar.
6) Install the connecting collar into the top of the unit until the bead of
the collar rests against the top of the inner top of the unit. Reach
inside the upper louver opening and use pliers to bend the tabs
(minimum 4) out on the connector collar. A hammer may be
required to lightly tap the tabs and bend them so that they fi t tightly
against the bottom of the inner top. Pull the insulation sleeve down
to the top of the unit. Repeat steps 1-6 for the second fl ex vent and
collar assembly.
7) Position the vent frames for the Discharge Grilles into the rough
opening of the stud wall framing. Make sure to add two insulation
strips behind the fl anges of the frame prior to securing to wall. The
frames will fi t between studs framed at 16” (406mm) on center. Use
4 nails or screws to mount the frame to the stud framing.
8) Insert the connecting collar into the other end of the 5 ft. (1.5m)
fl ex vent and use an adjustable clamp to hold the vent in place.
Cut tabs into the rim of the connector collar (a minimum of 4 tabs
will be required). Push the collar through the 8” (203mm) hole in
the mounting frame. Use pliers to bend out tabs (minimum 4) to
secure the collar to the mounting frame.
9) Pull the insulation sleeve up the fl ex vent to the back of the mounting
frame. The fl ex vent should now be connected to both the unit and
the mounting frames securely. Repeat steps 1-8 for the second fl ex
vent assembly.
10) Install the block-off plate to the unit. The block-off plate will cover
the upper louver opening of the unit and force the fan air to
circulate through the two 8” (203mm) diameter fl ex vents. Put high
temperature sealant onto the block-off plate. Mount the block-off
plate onto the front of the unit and cover the upper louver opening.
Make sure that all exposed holes in the block-off plate are sealed
with high temperature sealant
NOTE: Make sure the block-off plate is fl ush and
fastened tightly to the Regency R90 Fireplace.
11) The rough opening size for the Chase Vent Grille is 3” H x 10” W
(76mm H x 254mm W).
WARNING: A chase vent of 30 sq. inches (194 cm
2
)
MUST be installed in all applications, otherwise serious
overheating of the chase may result. Use the chase
vent supplied with the R90 unit only or any equivalent
one with the same or less restriction of air fl ow.
12) Recheck all fl ex vent-work connections to make sure that they are
secure. Install wall sheathing and cut-out openings for the chase
ventilation, and hot air discharge outlets.
13) Install the Chase Vent Grille and install the Discharge Vent Grilles
for the hot air outlets.
NOTE: There must be a minimum of 5" (127mm)
between the gravity air vents.