Regency P33S Indoor Fireplace User Manual


 
10” (P36/P36D/P42)/11"(P40)
Dia. hole through wall for
Flex or rigid venting
O
N
Combustible
material
Header
Non-combustible
material
10-1/4”(H)x42”(W)
1/2"
Drywall
Header
P40
P36/P36D/P42
MINIMUM TERMINATION CENTER LINE
P36/P36D/P40/P42
D
C
A
G
E (Dia. Int.)
F (Dia. Ext.)
P36/P36D/P40/P42
MINIMUM TERMINATION CENTER LINE
P33/P48
1/2"
Drywall
T op heade r
10" (P33) / 11”(P48) Dia. hole
through wall
for Flex or rigid venting
O
Framing (horizontal termination)
Minimum termi-
nation center line
H I J K* L M N O
P48 81-1/ 2" 57-5/8" 47-1/2 " 49 -1/2" 26 -1/4" 4 8-1/2" -- 43"
P42 63-5/16" 44-3/4" 36-5/8" 47-7/8" 19" 40-1/4" 35-5/8" 43"
P40** 71-5/8" 50-5/8" 42-1/2" 51-3/8" 20 -1/16" 40-1/2" 42-1/4" 45-3/8"
P36 60" 42-7/ 16 " 36-1/4" 46" 12-3/4" 36 -1/4" 36" 40-1/2"
P36 Deep 68" 48" 37-1/4" 4 6-1/2" 17-3/8" 36-1/4" 36" 40-1/2"
P36 Barcelona*** 60" 42-7/16" 36-1/4" 46" 12-3/4" 36 -1/4" 36" 40-1/2"
P36 Barcelona Deep*** 68" 48" 37-1/4" 4 6-1/2" 17-3/8" 36-1/4" 36" 40-1/2"
P36 Kensington*** 60" 42-7/ 16 " 36-1/4" 46" 12-3/4" 36 -1/4" 36" 40-1/2"
P36 Kensington Deep*** 68" 48" 37-1/4" 46 -1/2" 17-3/8" 36 -1/4" 36" 40-1/2"
P36 Balmoral*** 60" 42-7/ 16" 36 -1/4" 46" 12-3/4" 36 -1/4" 36" 40-1/2"
P36 Balmoral Deep*** 68" 48" 37-1/4" 4 6-1/ 2" 17-3/8" 3 6-1/4" 36" 40-1/2"
P36 Tripoli 60" 42-7/ 16" 36 -1/4" 46" 12-3/4" 36 -1/4" 36" 40-1/2"
P36 Tripoli Deep 68" 48" 37-1/4" 4 6-1/2" 17-3/8" 36-1/4" 36" 40-1/2"
P33 (Flex venting) 53-1/4" 37-1/2" 31-3/4" 31-7/ 8" 12-3/4" 33-1/4" -- 26"
P33 (Rigid venting) 53-1/4" 37-1/2" 31-3/4" 35-7/8" 16-1/2" 33-1/4" -- 30"
* When using rigid pipe.
** J=42-1/2" plus height of hearth.
*** The front face of the fireplace must be made of non-combustible material including framing. Framing material should be made of metal studs. See manual for details.
For vertical termination or vertical rise with horizontal termination please refer to manual.
A
B
A1
B1
Panorama direct vent replaces
C
A
D
E (Dia. Int.)
F (Dia. Ext.)
P33/P48
dimensions
A B A1 B1 C D E F G
P48 48" 41" 40-1/16" 23-5/16" 34 -1/2" 23-1/4" 5" 8" --
P42 40" 34" 32-7/8" 18-7/ 16 " 24 -1/4" 18-5/8" 4" 6-7/ 8" 11"
P40 40" 34" 32-1/ 2" 21-7/ 16 " 33-7/ 16 " 20 -1/16" 5" 8" 10-5/8"
P36D 36" 30-1/2" 29-3/16" 15-1/2" 33-1/4" 17-1/8" 4" 6-7/ 8" 11-1/4"
P36 36" 30 -1/2" 29-3/16" 15-1/2" 33-1/4" 12-3/4" 4" 6 -7/ 8" 7-1/4"
P33 33" 29" 26" 16" 23" 12-3/4" 4" 6 -7/ 8" --
H
I
FRAMING - TOP VIEW
P33/P48
FRAMING - FRONT VIEW
Minimum height
to combustible
material
L
M
J
K
Non-combustible
header
FRAMING - TOP VIEW
P36/P36D/P40/P42
H
I
framing
Front Framing Dimensions
Non-combustible
material
Min. 6”
Min.12”
Min. 6”
D
C
Steel
Stud
Steel
Stud
FRONT FRAMING DIMENSIONS***
P36 /P36D Barcelona, Kensington, Balmoral
F
ront
F
ram
i
ng
Di
mens
i
ons
Non-combustible
material
Min. 6”
Min.12”
Min. 6”
J
M
Steel
Stud
Steel
Stud
30-7/8”
27-1/2”
FRONT FRAMING DIMENSIONS***
P36 /P36D Tripoli
30