Regency L900-1 Indoor Fireplace User Manual


 
Regency
®
L900-1 Direct Vent Gas Fireplace 27
INSTALLATION
WIRING DIAGRAM
AERATION ADJUSTMENT
The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue ame or
close for a more yellow ame.
In order to adjust the aeration, the logs, grate
and burner will need to be removed to be able
to access the shutters.
Minimum Air Shutter Opening:
NG 1/8"
LP 1/2"
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can
cause improper and dangerous operation.
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
CAUTION: Carbon will be produced if air shutter
is tightly closed.
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT covered
under warranty.
INSTALLATION
NOTE: The #8 ground lug is located on
the outer left side of the unit.