Regency L676-LP1 Indoor Fireplace User Manual


 
L676-1 Gas Fireplace
Clearance: Dimension Measured From:
A: Mantel Height 16-1/2” (419mm) Minimum
B: Sidewall 14-3/4” (375mm) Side of replace opening
C: Ceiling 52” (1321mm) Top of replace opening
D: Mantel Depth 13” (330mm) Maximum
E: Alcove Width 84” (2134mm) Sidewall to Sidewall (Minimum)
F: Alcove Depth 36” (914mm) Front to back wall (Maximum)
Clearance Requirements:
Combustible Mantels
Because of the extreme heat this replace emits, the mantel clearances
are critical. Combustible mantel clearances from top of the front facing
are shown in the diagram below. Mantel may be installed anywhere in the
shaded area or higher.
Drywall
Mantel Clearances
2
0
12
6
4
810
Top of
Fireplace
Opening
13" (330mm)
3½"(89mm)
A
Standoff
B
C
Header
(Metal Stud)
0
10
15
20
25
14
Non-combustible
Facing
To Floor
D
1" (25mm)
Mantel Leg
Clearances
Combustible mantel leg
clearances as per diagram.
Clearances are from the
nished edge of the replace
opening.
Mantel
Clearances
From Top of
Fireplace Opening
A 31-1/16”
B 26-1/2”
C 17-1/2”
D 16-1/2”
Note:
A non-combustible mantel may
be installed at a lower height if
the framing is made of metal
studs covered with a non-com-
bustible board.
Ensure the paint that is used
on the mantel and the facing is
“heat resistant” or the paint may
discolour.
Regency Liberty L676 Gas Fireplace
Vertical Terminations:
Horizontal Terminations:
IMPORTANT NOTE
Combustible material can only be installed to the bottom
lip of the replace as shown below. The nished oor must
not come in contact with the front face of the replace.
Non-combustible material must act as a barrier between
the front face and nished oor.
Finished Floor
The maximum height that combustible oor can be
brought above the base of the unit is 3".