Regency L234 Indoor Fireplace User Manual


 
L234 Gas Insert
Model L234-NG L234-LP
Fuel Type Natural Gas Propane
Minimum Supply Pressure 5” W.C. (1.25 kPa) 12” W.C. (2.99 kPa)
Manifold Pressure - High 3.8” W.C. (0.95 kPa) 11” W.C. (2.74 kPa)
Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 2.9” W.C. (0.72 kPa)
Orifi ce Size -Altitude 0-4500 ft. #42 DMS #54 DMS
Minimum Input
Altitude 0-4500 ft. (0-1372m)
12,500 BTU/h
(3.66 kW)
11,000 BTU/h
(3.22 kW)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
23,500 BTU/h
(6.89 kW)
21,500 BTU/h
(6.30 kW)
Vent Sizing
3”x3” Co-linear
(Standard)
2”x3” Co-linear (Optional)
3”x3” Co-linear (Standard)
2”x3” Co-linear (Optional)
Minimum Fireplace Dimensions
The minimum fi replace dimensions for the FPI gas fi replace insert are
shown in the following diagrams:
Dimension Description
Contour
Faceplate
Contemporary
Faceplate
J Height 17” (432mm) 17” (432mm)
K Width 25” (635mm) 25” (635mm)
L Depth 14” (356mm) 14” (356mm)
N Rear Width 16” (406mm) 16” (406mm)
A
2
A
1
B
1
CC
Contour Faceplate
Contemporary Faceplate
B
2
F
H
E
G
D
60°
I
Dimension Description L234
A1 Contour Faceplate Width 27-1/2” (699mm)
B1 Contour Faceplate Height 20-3/4” (527mm)
A2 Contemporary Faceplate Width 27-3/4” (705mm)
B
2 Contemporary Faceplate Height 21” (533mm)
C Unit Width 19-1/2” (495mm)
D Unit Height 16-7/8” (429mm)
E Unit Depth 13” (330mm)
F Faceplate to Vent Centerline 11-3/4” (299mm)
G Contour Faceplate Depth 2-1/2” (64mm)
G Contemporary Faceplate Depth 3” (76mm)
H Height to Vent Collar 16-1/4” (413mm)
I
Air Intake Collar (Standard) 3” (76mm)
Air Intake Collar (Optional) 2” (51mm)
L234 Gas Insert
Approved Venting Systems
Flex Vent Systems: FPI AstroCap™ Flex Vent
L
M
J
K
N
123June 2007 Regency Product Specifi cations Book
Gas Inserts
Gas Inserts