SAFETY LABEL
This is a copy of the label that accompanies each
Regency Hearth Heater. We have printed a
copy of the contents here for your review.
103
DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR
ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. OPERATE WITH FEED DOOR CLOSED, OPEN TO FEED FIRE ONLY.
REPLACE GLASS ONLY WITH CERAMIC GLASS (5 MM).
INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY. DO
NOT OVERFIRE, IF INSERT GLOWS YOU ARE OVER-FIRING.
MANUFACTURED BY:
FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST. DELTA, BC V4G 1H4
UNITED STATES ENVIRONMENTAL PROTEC-
TION AGENCY CERTIFIED TO COMPLY WITH
JULY 1990, PARTICULATE EMISSION STAND-
ARDS.
908-389b 11/05
HOT WHILE IN OPERATION
DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE
SKIN BURNS. READ ABOVE
INSTRUCTIONS.
CAUTION
JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV DEC
ADJACENT SIDEWALL A) 10 in/ 255 mm
MANTEL B) 25 in/ 635 mm
TOP FACING C) 14 in/355 mm
SIDE FACING D) 8.5 in/216mm
HEARTH EXTENSION (DEPTH) E) 18 in/455 mm
HEARTH EXTENSION (ELEVATION) F) 1.5 in/38 mm
HEARTH EXTENSION (WIDTH) G)6 in / 150 mm
A
G
F
D
B
C
E
ADJAC
E
N
TSI
D
EW
A
LL
INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED (F) 1.5 IN / 38 MM ABOVE
AN ADJACENT COMBUSTIBLE FLOOR. COMBUSTIBLE FLOOR MUST BE PRO-
TECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING (E) 18 IN / 455 MM TO
FRONT AND (G) 6 IN / 150 MM TO SIDES.
COMPONENTS REQUIRED FOR INSTALLATION MUST HAVE A 6IN/150MM
STAINLESS STEEL LINER.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (MEASURED FROM INSERT BODY)
LISTED FACTORY BUILT FIREPLACE ACCESSORY HEARTH STOVE
CERTIFIED FOR USE IN CANADA AND U.S.A.
MODEL: H2100M
TESTED TO: ULC S628-M93 / UL 1482-1998 REPORT NO. 6255 (JULY 1991)
2005 2006 2007
DATE OF MANUFACTURE
MADE IN CANADA
(Duplicate Serial #)
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS. INSTALL AND USE ONLY IN MASONRY FIREPLACE OR
FACTORY BUILT FIREPLACE.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.
DO NOT REMOVE THIS LABEL
103
NOTE: Regency units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
SAFETY LABEL FOR H2100M