Regency H35 Indoor Fireplace User Manual


 
* The H15 can be vented horizontally with the AstroCap™ system. For rear vent applica-
tions, H25 requires a riser vent; H35 requires a riser vent and BTU reduction kit.
** H35 requires minimum 1ft. rise.
H15/H25/H35* H15/H25/H35** H15/H25/H35
D
D
A
A
B
A
A
C
Left Side Wall
Right Side Wall
Left Side Wall
Right Side Wall
Clearances To Combustibles H15 H25 H35
A Side Wall To Unit
6" 6" 6-1/2 "
B Back Wall To Unit
0" 3" 6"
C Vertical Vent to Back Wall
2" 2" 2"
D Side Wall To Unit (Corner)
2" 2" 2"
Minimum clearance of vent terminal to outside corner and inside corner: AstroCap™ 6", Dura-Vent Cap 12"
Dimensions H15 H25 H35
A
20-11/16" 22-5/8" 27"
B
22-1/2" 27" 28"
C
14 -1/4" 14-1/4" 19-3/4"
D
16-3/16" 16-7/16" 21"
Shipping Weight
182 lbs. 196 lbs. 308 lbs.
A
B
C
D
A
B
C
D
Hampton® Gas Products
Specifications
H15 H25 H35
NG LP NG LP NG LP
Maximum BTU
18,000 18,000 25,000 23,000 36,000 34,000
Turn down to (BTU)
10,500 10,600 12,500 11,500 18,000 1 7, 5 0 0
EnerGuide rating (Canada only)
62.31% 62.31% 61.15% 61.63% 68.34% 69.72%
Efficiency
80% 82% 83% 85% 83% 85%
Herringbone - Rustic Brown Standard - Rustic Brown
Standard - Old Town Red
FireGenie® Remote Control
Turn your Hampton on and o from the comfort of your
sofa with the easy-to-use FireGenie.
Programmable Thermostat
Set a specic temperature with a Hampton wall thermo-
stat and maintain a constant comfort level in your home.
Brick Panels
Add one of three fully textured brick panels.
Note: Herringbone is not available for the H35.
gas stoves
accessories
NOTE: PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. BEFORE INSTALLING REFER TO THE RELEVANT PRODUCT MANUAL FOR FULL AND UP
TO DATE INFORMATION.
H15: Tested to the following standards:ANSIZ21.88-2003/CSA33-2002, CGA 2-17-M91
H25: Tested to the following standards: Gas-Fired Appliances For Use At High Altitudes CGA 2-17-M91, Vented Gas Fireplace Heaters ANS Z21.88a-2000/CSA 2.33a-2000.
Certied for Canada and the US.
H35: Tested to the following standards: CGA 2-17-M91, ANSIZ21.88b-1999/CSA 2.33b-M99. Certied for Canada and the US.
H15, H25 and H35 are approved for bedroom, alcove and mobile home installations.
All products tested to the following standards: GRAVITY DIRECT VENT WALL FURNACE TESTED AND APPROVED FOR U.S.A. AND CANADA TO: CAN/CGA-2.17-M91, ANSI
Z21.88b-1999/CSA 2.33b-M99.
14