Regency H200 Stove User Manual


 
94 June 2007 Hampton Product Specifi cations Book
Wood Stoves
Wood Stoves
Unit (with heat Shield)
From Unit
From Vent
centerline
Min.
Width
Min. Hearth
to Rear Wall
GH I J K L
H200 15” 13” 27” 15-1/8” 54” 50”
Minimum Alcove Clearance To
Combustible Materials
Hampton Freestanding models have been alcove approved and must be
installed with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 60"
Maximum depth of alcove - 48"
*The rear clearance to combustibles is less than 6" (152mm), for corner
installations the rear corners may be angled to take advantage of the
closer clearances.
NOTE: In Canada, fl oor protection must extend 18" to the front
and 8" to each side of the stove.
Floor Protection
A combustible fl oor must be protected by a non-combustible material
(like tile, concrete board, or certifi ed to UL-1618 or as defi ned by local
codes) extending beneath the heater and a minimum of 6" from each
side and minimum 18" from the front face of the stove and minimum 6"
(or the rear clearance to combustibles whichever is smaller) from the
rear of the stove.
When installed with horizontal venting, non-combustible fl oor protection
must be installed underneath the fl ue pipe and extend 2" (51mm) beyond
each side.
Minimum Overall Width (X) of Floor
Protector for all installations:
H200 (US) 36"
H200 (Canada) 40”
Minimum Overall Depth (Y) of Floor Protector
Unit
Residential
“C” Vent
Residential
Close
Clearance
Mobile
Home Close
Clearance
Alcove
YZYZYZYZ
H200 (US) 43” 6” 43” 6” 43” 6” 43” 6”
H200 (Canada) 45” 8” 45” 8” 45” 8” 45” 8”
H200 Wood Stove
Mobile Home Close Clearance (To be installed with required pipe components)
“C” Vent single wall pipe is not approved for Mobile Home installations. (Refer to mobile home instructions.)
Unit (with heat Shield)
From Unit From Corner
From Vent
centerline
ABCDE F
H200 15” 10” 9” 27” 12-1/8” 15-7/8”
Additional Clearances For Backwall Exit
Unit (with heat Shield)
Minimum Clearances:
To Combustibles To Non-Combustibles
ABAB
H200 9” 15” 0-9” 15
Min. Mantel Height (from fi nished fl oor): 48”
Max. Mantel Depth: 12”
Note: Floor protection must extend 2” to each side of the elbow.