Regency H200 Stove User Manual


 
Model H200
Optimum Effi ciency 74%
Emissions (grams/hr) EPA Certifi ed 3.9 grams/hr
Maximum BTU* 38,800 BTU
Maximum Log Size 16”
Firebox Size 1.34 cu. ft.
Flue Size 6”
Burn Time (typical)* up to 6 hrs.
* Length of burn time and BTU Range depends on type of wood, climate conditions and
installation.
93June 2007 Hampton Product Specifi cations Book
Wood Stoves
Wood Stoves
H200 Cast Freestanding Woodstove
Residential Installation “C” Vent (Single Wall)
Unit (with heat Shield)
From Unit From Corner
From Vent
centerline
ABCDE F
H200 17” 15” 13” 29” 17-1/8” 19-7/8”
Minimum Clearance To Combustible
Materials
Please read the section below carefully as clearances depend on whether
the airmate or the rear heat defl ector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side
wall or to a corner, and from the rear heat shield to a back wall.
H200 Wood Stove
22-1/8” (562mm)
28-3/4” (729mm)
27-5/8” (703mm)
15” (380mm)
7-1/8”
(181mm)
5-3/8” (136mm
)
20-1/2” (522mm)
25-7/8” (659mm)
23-7/8” (606mm)
20-3/8” (519mm)
25-1/8” (639mm)
22-5/8” (574mm)
FAN
14-7/8”
(378mm)
6”
(152mm)
6”
(152mm)
1-1/4”
(32mm)
2”
(51mm)
Short Cast Leg
(Optional)
Short Cast Leg
(Optional)
Cast Side Shelf
(Optional)
Residential Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required
from the stove collar to the ceiling level.
Unit (with heat Shield)
From Unit From Corner
From Vent
centerline
ABCDE F
H200 15” 10” 9” 27” 12-1/8” 15-7/8”