14 Regency F38-2 Freestanding Gas Stove
OPERATING INSTRUCTIONS
4) Turn the PILOT knob counterclockwise to
pilot and align it with the arrow as shown
in diagram 1.
5) Push in PILOT knob all the way in and hold.
Immediately push IGNITOR button until pilot
lights. Continue to hold the PILOT knob in
for approximately one minute, then release
the PILOT knob. The pilot fl ame should
continue to burn. If the pilot does not remain
lit, repeat operation allowing a longer period
before releasing PILOT knob.
6) Turn PILOT knob counter clockwise to
on.
7) Use the ON/OFF switch to turn on the
burner.
8) Rotate the HEAT control to adjust the fl ame
height higher or lower.
SHUTDOWN
INSTRUCTIONS
1) Use the ON/OFF switch, wall switch,
thermostat or remote control to turn off the
burner.
2) Push in the PILOT knob slightly and turn
clockwise to off. Do not force.
3) Turn off all electric power to the appliance
if service is to be performed.
FIRST FIRE
The FIRST FIRE in your heater is part of the
paint curing process. To ensure that the paint
is properly cured, it is recommended that you
burn your fi replace for at least four (4) hours the
fi rst time you use it with the fan on.
When fi rst operated, the unit will release an
odour caused by the curing of the paint and the
burning off of any oils remaining from manufac-
turing. Smoke detectors in the house may go
off at this time. Open a few windows to ventilate
the room for a couple of hours. The glass may
require cleaning.
DO NOT ATTEMPT TO CLEAN THE GLASS
WHILE IT IS STILL HOT!
Note: When the glass is cold and the appli-
ance is lit, it may cause condensation
and fog the glass. This condensation
is normal and will disappear in a few
minutes as the glass heats up.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
OPERATING
INSTRUCTIONS
Before operating this appliance, proceed through
the following check list.
1) Read and understand these Instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the three pieces of door glass
are properly positioned. Never operate the
appliance with any of the glass removed or
with the door open.
5) Verify that all fl ueing and the cap is unob-
structed.
6) Verify log placement. If the pilot cannot be
seen when lighting the unit - the logs or the
embers have been incorrectly positioned.
7) The unit should never to turned off and on
without a minimum of a 60 second wait.
LIGHTING
INSTRUCTIONS
IMPORTANT: The PILOT knob cannot be
turned from pilot to off unless it is partially
depressed.
Note: Open the pedestal door of the unit
before lighting the pilot. Once the
pilot is lit, close the door. You should
never operate the unit with the door
open.
1) If the PILOT knob is in the off position
proceed to Step 4.
Diagram 1
2) Push in PILOT knob slightly and turn clock-
wise to off. Knob cannot be turned from
pilot to off unless knob is pushed in slightly.
Do not force.
3) Wait fi ve minutes to allow gas, that may have
accumulated in the main burner compart-
ment, to escape. If you smell gas, follow
the instructions on the front of this manual.
If you don't smell gas continue on to the next
step.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
WARNING
DO NOT SPRAY AEROSOLS IN
THE VICINITY OF THIS
APPLIANCE WHILE IN
OPERATION
ADJUSTING FLAME
HEIGHT
Your heater has an adjustable fl ame to tailor the
look and heat output to your specifi c needs. It
is adjusted by turning the fl ame adjustment dial
on the gas control valve.
Turn clockwise to adjust the fl ame higher, coun-
terclockwise for a lower fl ame.
AUTOMATIC
CONVECTION
FAN OPERATION
Set the fan speed on
control panel at the
top rear of the unit to
adjust to the desired
speed. The fan will
turn on as the stove
comes up to operating
temperature. After the
unit has been turned
off and the unit cooled
to below a useful heat
output range the fan
will shut off automati-
cally.