Regency E33S Indoor Fireplace User Manual


 
L
M
J
K
N
Model E33S-NG1 E33S-LP1
Fuel Type Natural Gas Propane
Minimum Supply Pressure 5” W.C. (1.25 kPa) 12” W.C. (2.99 kPa)
Manifold Pressure - High 3.8” W.C. (0.95 kPa) 11” W.C. (2.74 kPa)
Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 2.9” W.C. (0.72 kPa)
Orifice Size -
Altitude 0-4500 ft. #42 DMS #54 DMS
Minimum Input
Altitude 0-4500 ft. (0-1372m)
13,500 BTU/h
(3.95 kW)
12,000 BTU/h
(3.51 kW)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
26,000 BTU/h
(7.61 kW)
23,000 BTU/h
(6.74 kW)
Vent Sizing
3” Co-linear 3” Co-linear
Minimum Fireplace Dimensions
The minimum fireplace dimensions for the FPI gas fireplace insert are
shown in the following diagrams:
Dimension Description E33S
J Height 24-3/16” (614mm)
K Width 32-1/4” (819mm)
L Depth 16-3/4” (426mm)
M Max. Lintel Bar Depth 8” (203mm)
N Rear Width 25” (635mm)
Dimension Description E33S
A Faceplate Width 46-3/4” (1187mm)
B Faceplate Height 30-5/8” (778mm)
C Unit Width 32-1/8” (816mm)
D Unit Height 23-3/4” (603mm)
E Unit Depth 16-1/2” (419mm)
F Faceplate to Vent Centerline 11-3/8” (290mm)
G Faceplate Depth 1-1/8” (28mm)
H Height to Vent Collar 22-7/8” (581mm)
I Faceplate Depth 2-7/8” (72mm)
Approved Venting Systems
Flex Vent Systems: FPI AstroCap™ Flex Vent
Regency E33 Sunrise Gas Insert
WARNING
Failure to maintain required clearances is a major cause of chimney related fires.
Installation of this fireplace must comply with these clearances
Please note: Due to ongoing product development, product appearance and specifications
are subject to change without notice.
This manual is intended to be a Sales Reference Guide only.
Do NOT use for actual framing and installation of any unit.
Some specifications may change without notice.
You must use the actual manual for exact installation specifications.
E33S Sunrise Gas Insert