Regency E33-NG1 Indoor Fireplace User Manual


 
Clearances
Unless otherwise stated the clearances listed below are Minimum
distances to combustible materials. Please Note: A major cause
of chimney related fi res is due to a failure to maintain required
clearances (air space) to combustible materials. It is of the greatest
importance that this fi replace and vent system be installed only in
accordance with these instructions.
Combustible Mantels
Because of the extreme heat this fi replace emits, the mantel
clearances are critical. Combustible mantel clearances from top of
the louvers are shown in the diagram below. Mantel may be installed
anywhere in the shaded area or higher.
Note: A non-combustible mantel may be installed at a lower
height.
Note: Ensure the paint that is used on the mantel and the facing
is “heat resistant” or the paint may discolour.
Clearances to Combustibles
Dimension Description E33
A* From Unit to Side Walls 8” (203mm)
B From Unit to Ceiling 47” (1194mm)
C Minimum Mantel Height 15” (381mm)
D Maximum Mantel Depth 12” (305mm)
E Alcove Width 76” (1930mm)
F Alcove Depth 36” (914mm)
G Hearth Height 1-¼” (32mm)
H Hearth Width 45-½” (1156mm)
I Hearth Depth 13” (330mm)
* Alcove side wall must have a minimum of 8” (203mm) clearance on one side.
25" (635mm)
to floor
Side View
12" (305mm) Mantel
3-1/2" (89mm) Mantel
20”
(508mm)
47”
(1194mm)
to ceiling
15”
(381mm)
2
0
12
6
4
810
2
0
12
6
16
4
14
8
18
20
10
Top of
Unit
Flush Front Mantel Clearances
Full Screen Door Mantel Clearances
E33 Gas Insert
D
128 June 2007 Regency Product Specifi cations Book
Gas Inserts