4
Regency E21 Gas Fireplace Insert
SAFETY LABEL
This is a copy of the label that accompanies
each Regency Gas Insert. We have printed
a copy of the contents here for your review.
The safety label is located on the front inside
base of the unit visible when the bottom louver
is open.
Note: Regency units are constantly being
improved. Check the label on the unit
and if there is a difference, the label
on the unit is the correct one.
Please note that with the addition
of thermostat control and outside
combustion air supply, this unit is
approved for bedroom installations.
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
Listed:
VENTED
GAS
FIREPLACE
HEATER
Tested
to:
ANSI
Z21.88b-2003/CSA-2.33b-2003,
CGA
2.17-M91
Gas
fired
appliance
for
use
at
high
altitude.
Certified
for/Certifee
pour:
CANADA
and
U.S.A.
Report
No.
476-1428-00
(DEC.
2000)
Model/
Modele:
DO
NOT
REMOVE
THIS
LABEL/
NE
PAS
ENLEVER
CETTE
ÉTIQUETTE
276
Serial
No./
No
de
Serie
918-355a
Minimum
Clearances
to
Combustibles/
Degagement
Minimum
Des
Materiaux
Combustibles:
Side
of
unit
to
wall
/
Cote:
A
9"/229mm
Top
of
unit
to
mantle
/
Au
dessus:
B
14"/355mm
MADE
IN
CANADA
/
FABRIQUE
AU
CANADA
FPI
Fireplace
Products
International
Ltd.,
Delta,
B.C.,
Canada
FIREPLACE
INSERT:
E21-NG1
E21-LP1
APPAREIL
FONCTIONNANT
CONCU
POUR
Natural
Gas
(Naturel
Gaz)
Propan
e
ETRE
INSERE
DANS
UN
FOYER
Minimum
supply
pressure
5.0"
WC/C.E.
(1.25
kPa)
12.0"
WC/C.E.
(2.99
kPa)
Pression
d’alimentation
minimum
Manifold
pressure
high
3.8"
WC/C.E.
(0.95
kPa)
11.0"
WC/C.E.
(2.74
kPa)
Pression
tublure
d'échappement
élevée
Manifold
pressure
low
1.1"
WC/C.E.
(0.27
kPa)
2.9"
WC/C.E.
(0.72
kPa)
Pression
tublure
d'échappement
basse
Altitude
0-2000
ft.
2000
-
4500
ft.
0-4500
ft.
L'altitude
(0
-
610m)
(610
-
1372m)
(0-1372m)
Orifice
size
43
DMS
44
DMS
54
DMS
Grandeur
de
l’injecteur
Maximum
input
23,500
Btu/h
22,000
Btu/h
22,500
Btu/h
Debit
calorifique
maximum
Minimum
input
11,750
Btu/h
11,000
Btu/h
11,250
Btu/h
Debit
calorifique
minimum
Duplicate
Serial
No.
NOT
FOR
USE
WITH
SOLID
FUEL.
NE
PAS
UTILISER
AVEC
DU
COMBUSTIBLE
SOLIDE.
For
installation
into
a
vented
non-combustible
fire-
place,
listed
factory
built
fireplace.
This
vented
gas
fireplace
heater
is
not
for
use
with
air
filters.
Ne
peut
etre
installe
que
dans
un
foyer
non
combustible
muni
d'un
event.
Ne
pas
utiliser
de
filtre
à
air
avec
ce
foyer
au
gaz
à
é
vacuation.
WARNING
: This fireplace has been converted
for
use
with
a
gas
fireplace
insert
only
and
cannot
be
used
for
burning
wood
or
solid
fuels
unless
all
original
parts
have
been
replaced,
and
the
fireplace
re-approved
by
the
authority
having
jurisdiction.ELECTRICAL
SUPPLY/ALIMENTATION
ELECTRIQUE:115V60HZ
less
than/Moins
de
2
AMP.
E21-NG1
E21-LP1
276