Regency CLASSIC C33-2 Freestanding Gas Stove
This is a copy of the label that accompanies
each CLASSIC Freestanding Gas Stove - Nat-
ural Gas. We have printed a copy of the
contents here for your review. The safety label
is located on the back panel.
NOTE: Regency units are constantly being
improved. Check the label on the unit and if there
is a difference, the label on the unit is the correct
one.
SAFETY LABEL
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
Listed: VENTED GAS FIREPLACE HEATER
Certified for:
Report No.
CANADA and USA
476-1345-00 (Oct. 1996)
FPI Fireplace Products International Ltd.
Delta, BC, Canada
FACTORY EQUIPPED FOR NATURAL GAS:
Model C33-NG2
Minimum supply pressure 5" WC/C.E. (1.25Kpa)
Manifold pressure High 3.8" WC/C.E. (0.94Kpa)
Manifold pressure Low 1.1" WC/C.E. (0.27Kpa)
Orifice size 36 DMS
Altitude 0-2000 ft/pi (0-610 m)
Maximum Input 33,000 BTUH (9.67Kw/h)
Minimum Input 17,000 BTUH (4.98Kw/h)
Factory Equipped for 0-2000 ft.
Minimum supply pressure 5" WC/C.E. (1.25Kpa)
Manifold pressure High 3.8" WC/C.E. (0.94Kpa)
Manifold pressure Low 1.1" WC/C.E. (0.27Kpa)
Orifice size 38 DMS
Altitude 2000-4500 ft/pi (610-1370m)
Maximum Input 29,000 BTUH (8.5Kw/h)
Minimum Input 15,300 BTUH (4.48Kw/h)
Serial No.
201
201
HIGH ALTITUDE CONVERTED NATURAL GAS:
Model C33-NG2
Field Convertable for Altitude 2000-4500 ft.
Made in Canada
908-634b
DO NOT REMOVE THIS LABEL
Minimum Clearances to Combustibles
Back wall
Side wall
E
A - 10"
E - 1.5"
Minimum ceiling height from top of unit: 36"/914mm
A
A
B
Back wall
Side wall
Side wall
This appliance must be installed in accordance with
local codes, if any; if none, follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and
Propane Installation Codes, CSA B149.1.
FOR USE WITH GLASS DOORS CERTIFIED
WITH APPLIANCE ONLY.
This vented gas fireplace heater is
not for use with air filters.
Electrical Supply (115 V, 1.13A, 60 Hz)
Optional Fan: (Part #490-917)
Not for use with solid fuel.
Duplicate
Serial No.
B-6"
Tested to: ANSI Z21.88b-2003/CSA 2.33b-2003,
CAN/CGA-2.17-M91