Raypak RHP 115HC Heat Pump User Manual


 
34-1/2
37
2"
WATER
CONNECTION
34-1/2
8
10-7/16
4-11/16
2151 Eastman Avenue, Oxnard CA 93030 • (805) 278-5300 Fax (800) 872-9725
www.raypak.com
•Exclusive DuraSteel
TM
Cabinet
Polyester-coated, non-corrosive cabinet is more durable than
plastic heat pump cabinets.
Large Coated Air Coils
Large fins maximize heating at lower temperatures. Unique
fin coating prevents corrosion, even in salt air.
•Venturi Fan Cowling
High capacity fan provides unrestricted air flow for better
heating.
Solid State Controls
Accurately monitor your pool’s water temperature settings.
•Internal Valving
Automatically compensates for normal day-to-day changes in
your pool’s hydraulics, maximizing heat transfer efficiency.
•Back-Flow Check Valves
Reduce the possibility of damage from chlorinating devices.
•Exclusive Refrigerant Receiver Tank
Allows larger refrigerant charge and provides more efficient
heating at lower air temperatures without additional
compressor stress.
Features and Benefits
Catalog Number: 6000.25B Effective 04-01-04 Replaces 09-01-02
Raypak reserves the right to change these specifications without notice.
All dimensions are in inches.
RHP 115HC Heat Pump
Dimensions and Technical Specifications
MODEL 115HC
Heat BTUH Output 112,000
80°F Air 80% RH 80°F Water
Cool BTUH Output 83,000
C.O.P. 6.4
Compressor Scroll
Voltage 208/230V-1Ph-60Hz
Minimum Circuit Ampacity 40
Maximum Breaker Size (Amps) 50
Electrical Input (kw) 5.12
Water Flow (gpm) 15-80
Shipping Weight (lbs) 335
Every Raypak heat pump is built with a copper-jacketed,
cupronickel interior heat exchanger.
Inside the heat exchanger, the water tube is a rifled cupronickel
pathway which provides 25% more surface area and up to 15%
more heat transfer.
Heat Exchanger Cross section of cupronickel
water tube
Heat it....Cool it,
set it and forget it!
Compressor
The heart of any heat pump is its
compressor. A Copeland®
Compliant Scroll® compressor is the
quietest and most efficient in the
world. While offered as an upgrade
by other manufacturers, it’s standard
in a Raypak heat pump. To ensure
the quietest operation possible,
Raypak mounts all its scroll
compressors on rubber isolation
cushions, helping to eliminate
any cabinet vibration.