RHP-115LHHC
State-of-the-art control panel,
with Direct Set temperature
control and LED
temperature readout. LED
lights monitor the heat
pumps’ operational status
at all times.
34-1/2
37
2"
WATER
CONNECTION
34-1/2
8
10-7/16
4-11/16
2151 Eastman Avenue, Oxnard CA 93030 • (805) 278-5300 Fax (800) 872-9725
www.raypak.com
•Exclusive DuraSteel
TM
Cabinet
Polyester coated, non-corrosive cabinet is more durable than
plastic heat pump cabinets.
•Oversized Coated Air Coils
Oversized fins maximize heating in low humidity conditions.
Unique fin coating prevents corrosion, even in salt air.
•Venturi Fan Cowling
High capacity fan provides unrestricted air flow for better
heating.
• 10 Year Limited Warranty
Customer direct toll free number 800-260-2758
• Solid State Controls
Accurately monitors your pool’s water temperature settings.
•Internal Valving
Automatically compensates for normal day-to-day changes in
your pool’s hydraulics, maximizing heat transfer efficiency.
•Back-Flow Check Valves
Reduce the possibility of damage from chlorinating devices.
•Exclusive Refrigerant Receiver Tank
Allows larger refrigerant charge and provides more efficient
heating at lower air temperatures without additional
compressor stress.
•System Compatibility
Compatible with the latest automated pool control systems.
Features and Benefits
Catalog Number: 6000.26A Effective 08-06-02 Replaces 04-01-02
Raypak reserves the right to change these specifications without notice.
All dimensions
are in inches.
RHP-115LH
RHP-115LHHC Heat Pumps
Dimensions and Technical Specifications
MODEL 115LH 115LHHC
Heat BTU Output 112,000 112,000
80°F Air 80% RH 80°F Water
Cool BTU Output N/A 83,000
C.O.P. 6.4 6.4
Compressor Scroll Scroll
Voltage 208/230V-1Ph-60Hz
Minimum Circuit Ampacity 40 40
Maximum Breaker Size (Amps) 50 50
Electrical Input (kw) 5.12 5.12
Water Flow (gpm) 15-80 15-80
Shipping Weight (lbs.) 375 385
ETL tested and rated in accordance with ASHRAE standard 146-198 and PHPMA
addendum test procedure.
A standard heat
pump coil can not
gather enough
moisture to generate
adequate heat in a
dry climate.
The coil in a Raypak
LH heat pump is
oversized, which
allows it to gather
more moisture from
the air. More moisture
equals more heat.
Standard Coil Size
Raypak LH Oversized Coil
Dry Air? Desert climates not a problem!
You can heat and cool with
the RHP-115LHHC
LHHC Series control
panel shown