Raypak H-0042B Boiler User Manual


 
USER'S INFORMATION MANUAL
GAS FIRED RESIDENTIAL
HEATING BOILERS
WARNING: If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids or other
combustible materials in the vicinity of this or any other appliance. To do so may
result in an explosion or fire.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency
or the gas supplier.
MODELS H- 0030B, 0042B, 0066B, 0090B, 0135B, 0180B
This User's Information Manual is provided with the
necessary information for the proper operation and main-
tenance of these Raypak boilers. Please review and follow
these procedures carefully. Keep this manual in a safe
and accessible place for easy reference in the future.
BLOCKED VENT SHUT-OFF SYSTEM
This boiler is equipped with a blocked vent shut-off
system designed to shut off main burner gas in the event
the venting system is totally blocked.
In the event the blocked vent shut-off system is actu-
ated, do not attempt to place the boiler in operation, but
contact a qualified service agency.
FLAME ROLL-OUT SAFETY SHUT-OFF SYSTEM
This boiler is equipped with a flame roll-out safety shut-
off system designed to shut-off the main burner gas in the
event of sustained flame roll-out.
In the event the flame roll-out safety system is actu-
ated, do not attempt to place the boiler in operation, but
contact a qualified service agency.
CAUTION: Improper care and maintenance of flue and
venting system can cause a hazardous condition which
may result in injury or property damage.
LIGHTING INSTRUCTIONS FOR
STANDING PILOT MODELS.
Some safety information you need to read and under-
stand before operating the boiler.
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
A. This boiler has a pilot which must be lighted by
hand. When lighting the pilot, follow these instruc-
tions exactly.
B. BEFORE LIGHTING Smell all around the boiler
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch;
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neigh-
bor's phone. Follow the gas supplier's instruc-
tions
• If you cannot reach you gas supplier, call the
fire department.
C. Use only your hand to push in move or turn the
gas control knob or lever. Never use tools. If the
knob or lever will not push in move or turn by hand,
P/N 240490
CATALOG NO: 2100.51-J
Effective: 06-15-00
Replaces: 11-01-99