Raypak 8300 Heat Pump User Manual


 
5
V. System Start-Up
1. Verify that the Power lamp is ON and that the pool/spa pump is running and circulating
properly.
2. Verify that the control panel Spa-Remote-Pool switch is in the Remote (OFF) position; see
the figure.
3. Turn the control switch to either Pool or Spa to turn the system ON and raise the thermostat
setting above the current water temperature. At this time the 2 green lamps should illuminate.
The fan and compressor should start up and run simultaneously.
NOTE: The heat pump will not run when the Remote
position is selected on the Pool/Spa selector switch and
there is no remote control system attached.
4.Allow the heat pump to operate for a few minutes to
stabilize operating pressures and to allow various
component temperatures to normalize.
5. Verify that the discharge air temperature is
approximately 8° - 10° cooler than the air entering the
unit. If not, see Troubleshooting, Section XI.
VI. Seasonal Start-Up or Annual Check
NOTE: At the beginning of the heating season, or whenever the pool water temper-
ature is to be raised several degrees, the pool pump and heat pump may need to
operate continuously for several days. During summer months, only a few hours
per day may be necessary, or none at all.
1. Remove leaves, pine needles, etc. from the evaporator coil. Clean the coil by gently applying
a mild solution of household liquid soap and water.
2. Gently rinse the coil with water; do NOT use high pressure.
3. Backwash or otherwise clean the pool filter. If necessary, clean the skimmer basket and pump
strainer.
4. Replace the front and back caps; see the Series Hookup Diagram on the last page of this
manual for cap location.
5. Set the valves to assure proper water flow through the unit.
NOTE: If the pool pump and heat pump shut OFF before the water temperature is
raised to the desired level, you must lengthen the running time of both. To do this,
reset the time clock dial for the longer running time, or manually operate the pump
with the timer override switch. Since the heat pump capacity and efficiency are both
greater at higher ambient air temperatures, run time should be set to take
advantage of all daylight hours, when the air is generally warmer.
Spa thermostat
Pool/Spa selector
Pool thermostat
switch
CAUTION
To clean the fins, spray gently with a garden hose.
pressure wash, which will bend the fins and can void the warranty.
DO NOT